Which inverter for your house? Count what runs in a cut, then do one sum
Sashikesh Kumar, Diploma in Electrical · checked against V-Guard's sizing guide, 13 Nov 2026
The short answer
VA needed = (watts × 1.25) ÷ 0.8
Add the watts of only what you will run during a power cut, then use V-Guard's formula. The 1.25 keeps a 25% cushion; the 0.8 turns watts into the VA printed on the inverter.
≤ 600 W
Prime 1100950 VA / 760 W. Lights, fans, TV, router in 1 to 3 rooms.
600–730 W
Prime 15501300 VA / 910 W. Three rooms plus a fridge, or a cooler.
AC, iron, geyser
Not on these twoThey need a much bigger set. We can order one.
Your load decides the model
Appliance watts are V-Guard's figures (LED 15 W, fan 75 W, TV 80 W, router 15 W, laptop 90 W, fridge 200 W). Limits = the formula run backwards, with the 25% cushion kept.
Step 1 · start from your rooms
Don't start from VA. Start from what you want running when the light goes
In a Muzaffarpur summer the cut comes in the evening heat. Most families want fans and lights in the rooms they sit in, the TV, and the Wi-Fi. Everything else can wait for the power to come back.
Cooler 180 W is a usual figure for a room cooler; read the plate on yours. Old fans can draw 90 W or more and five-star fans much less, which moves the total either way. Leave out what can wait: every extra 100 W pushes you towards the bigger model. Which appliances are fine and which are not is on what runs on an inverter; fans, the biggest item on most lists, are on fans on inverter.
Step 2 · the sum
V-Guard's formula, worked once for a 3-room house
An inverter's box gives VA. Your appliances give watts. The formula joins the two and keeps a safety margin.
1Add the watts
Six LED lights, three fans, TV, router and a laptop:
500 W
Only the things that will be on at the same time.
2× 1.25 for a cushion
V-Guard adds 25% so the inverter never runs flat out, and so one motor starting up has room.
500 × 1.25 = 625
3÷ 0.8 to get VA
0.8 is the power factor V-Guard uses: each VA gives about 0.8 W of real power.
625 ÷ 0.8 = 781 VA
Prime 1100 is 950 VA: it fits.
Why we stop the Prime 1550 at about 730 W, not 830 W. Run backwards on its 1300 VA, the formula allows 832 W. But the 1550's own watt rating (on our purchase bill) is 910 W, and 910 ÷ 1.25 is 728 W. We check both and use the lower one. For the Prime 1100 both checks give the same 608 W (950 VA, 760 W). Luminous suggests a 20 to 25% margin and Okaya says to take the next model above your figure; V-Guard's 25% is the safest of the three, so we use it.
Step 3 · your own house
Tick what runs in your power cut
Set the count for each item. The page adds the watts, runs V-Guard's formula and names the model. For backup hours, use the inverter and battery calculator.
Your inverter
Load in a cut—All the items above, running together
Price for the inverter and battery together: Ask rate (combos). How many hours this load will run: backup hours guide.
Step 4 · two warnings
Motors jump at start. An AC is a different conversation
What the inverter sees when the fridge starts
Count generously
Fridge, cooler, pump, mixer
Anything with a motor pulls 2 to 3 times its running watts for a moment when it starts (V-Guard). The 25% cushion takes one such jump. If a fridge and another motor can start together, V-Guard's advice is to go one model up. That is why a fridge usually moves a 3-room house to the Prime 1550.
Not on these two
AC, geyser, iron, 1 HP pump
In Muzaffarpur most homes fit 1 ton or 1.5 ton split ACs. Either draws more than a Prime can carry, and more again at start. Heaters (geyser, iron, room heater) draw around a thousand watts or more. A 1 HP pump runs at 746 W before its start jump. These need a much larger inverter and battery bank; we can order one for you, so send us the AC's plate on WhatsApp first.
Fine
Lights, fans, TV, router, chargers
Small, steady loads with no big start jump. This is the list a home inverter is made for. Wiring the inverter only to these points is covered in inverter wiring points.
Step 5 · then the battery
The inverter decides what runs. The battery decides for how long
A bigger inverter does not give more hours; a bigger battery does. Both Prime models take one battery from 80 to 230 Ah, flat or tubular (V-Guard). Most houses pair the Prime 1100 with the VT 165 and the Prime 1550 with the VT 250 for long summer cuts. Working out the hours for your load is a separate page: how many hours of backup.
Buy the inverter and battery together. An inverter bought today with a battery "later" gets an old or local battery that never matches it. Our inverter and battery combos are matched for you, and an old battery, even a dead one or one bought elsewhere, is taken in exchange by weight at the day's scrap rate.
What we see at the counter
Four ways people buy the wrong size
Listing the whole house
Geyser, iron and mixer on the list push you to a set you don't need. Only count what runs in a cut.
Buying the biggest VA
More VA costs more and gives no extra hours. Size for your load plus 25%, and spend the rest on the battery.
Forgetting the fridge's jump
A 600 W total with a fridge on it sits right at the Prime 1100's edge. When the compressor starts, it beeps. Go one model up.
Planning the AC on it
A home inverter for lights and fans will not run a split AC. Ask before you wire the AC point to it.
On our shelf for this job
V-Guard inverters and batteries, with a GST bill
Inverters
Prices are from our latest bill and change often. Please confirm today's rate on WhatsApp or call before buying.
VA and watts are from our V-Guard purchase bill; V-Guard's own page gives the 1550's 1300 VA. A bigger inverter, a 24 V set or any other model: we can order it for you; ask on WhatsApp for the time it takes. Battery warranty claims: bring the battery, warranty card and bill to us and we send it to V-Guard.
Questions people ask us
Short answers
How many VA inverter do I need? (ghar ke liye kitne VA ka inverter)
Add the watts of only what you will run in a power cut, multiply by 1.25 and divide by 0.8 (V-Guard's formula). Three rooms with LED lights, fans, a TV, a router and a laptop come to about 500 W, which needs about 780 VA: the 950 VA Prime 1100 covers it.
Can one inverter run fans, lights, TV and a fridge together?
Yes, if the total fits. Three rooms of lights and fans with a TV, router and laptop is about 500 W; add a 200 W fridge and it is about 700 W, which needs the Prime 1550. Keep the cooler off when the fridge is on the same inverter, or go one size up.
Prime 1100 or Prime 1550 for a 3-room house?
Without a fridge or cooler on the inverter, the Prime 1100 is usually enough. With a fridge, or a cooler plus several fans, take the Prime 1550. Add your own watts in the box above first.
Can I run an AC on a home inverter?
Not on these two. A 1 ton or 1.5 ton split AC draws more than either Prime can carry, especially at start. It needs a much larger inverter and battery bank, which we can order for you.
Is a bigger inverter always better?
No. Size the inverter for your load with the 25% cushion. More VA costs more and does not give more hours; hours come from the battery. See how many hours of backup.
Why does my inverter beep when the fridge or motor starts?
Motors pull 2 to 3 times their running watts for a moment when they start (V-Guard). If the inverter is already near its limit, that jump overloads it. Switch off the cooler for that minute or go one model up.
Sashikesh Kumar
Diploma in Electrical, Tashya Ventures
Looks after wires, switchgear, inverters and pumps at our Reva Road store, Muzaffarpur. The formula, appliance watts and motor rule on this page were checked against V-Guard's own sizing guide on 13 Nov 2026, and the inverter ratings against our V-Guard bill. Where two figures could be used, the page uses the safer one.
Where the numbers come from
V-Guard, The Complete Inverter & Battery Sizing Guide: VA = (load × 1.25) ÷ 0.8, power factor 0.8, 25% cushion, appliance watts (LED 15 W, fan 75 W, TV up to 43" 80 W, router 15 W, laptop 90 W, fridge 200 W), motors 2–3× at start, one tier up if two motors may start together.
V-Guard, Prime 1550 product page: 1300 VA, pure sine wave, 80–230 Ah flat or tubular battery, EV two-wheeler charger up to 350 W.