हिंदी Call90310 74624
Home›Fans
Fans · V-Guard · Rewa Road

Which fan for which room: ceiling, BLDC, pedestal and exhaust fans at Rewa Road, Muzaffarpur

The short answer

Measure the room in feet, then pick the sweep. Up to about 10 × 10 ft takes a 900 mm fan, about 12 × 13 ft takes 1200 mm, about 14 × 16 ft takes 1400 mm. A bigger or long, narrow room gets two fans. A normal fan is cheaper to buy (our V-Guard Haize VX 1200 mm draws 53 W). A BLDC fan draws about 32 W and pays off in an inverter house or where the fan runs 8 hours or more. A kitchen or bathroom needs an exhaust fan, not a ceiling fan.

900 · 1200 · 1400
mm sweepFor about 10×10, 12×13 and 14×16 ft rooms (Havells' room table).
53 W · 32 W
normal vs BLDCHaize VX 1200 mm (V-Guard) against a BLDC fan (Havells).
150–250
mm exhaust fanChosen by how much air the room must change.

Every fan below can be ordered. The Haize VX 1200 mm and the Finesta Neo pedestal fan are on the shelf. We sell genuine V-Guard with a GST bill. For today's price, WhatsApp us the room size.

Three rooms, three fans, to scale
Three rooms with a ceiling fan each, drawn to scaleTop view of three rooms: 10 by 10 feet with a 900 mm fan, 12 by 13 feet with a 1200 mm fan, and 14 by 16 feet with a 1400 mm fan. The 1200 mm fan is marked as on our shelf.900 mmup to 10 × 10 ftwe order it1200 mmabout 12 × 13 fton our shelf1400 mmabout 14 × 16 ftwe order it10 ft
Room outlines and fan circles share one scale (the red bar is 10 ft). Room sizes are Havells' table turned into feet; the circle is the blade sweep.
Pick in a minute

Tell us the room, get the fan

Type your room in feet. The answer names the sweep, normal or BLDC, how far the fan hangs, and writes the WhatsApp message for you. For a kitchen or bathroom it gives the exhaust size.

Fan size

900, 1200 or 1400 mm: read it off the room

Havells publishes a room-size table for ceiling fans. Here it is in feet, with what we have against each size.

SweepRoom, metresRoom, feetUsual placeOurs
600 mm1.2 × 2 mabout 4 × 6.5 ftVerandah corner, passage, pantryWe order it
900 mm3 × 3 mabout 10 × 10 ftGuest room, small bedroomHaize VX 900: we order it
1200 mm3.6 × 4 mabout 12 × 13 ftBedroom, living room, diningHaize VX 1200: on the shelf
1400 mm4.2 × 4.8 mabout 14 × 16 ftHall, shop, big roomWe order it

Source: Havells' fan guide for the room sizes; Atomberg's guide also gives 900, 1200 and 1400 mm for small, medium and large rooms. Larger than 14 × 16 ft, or long and narrow, take two fans. Between two sizes, take the larger for a bedroom where people sleep under the fan. Details: fan size by room.

Watts and units, one fan
Watts drawn by a 900 mm Haize, a 1200 mm Haize and a BLDC fanThree bars: Haize VX 900 mm 40 watts, 12 units a month; Haize VX 1200 mm 53 watts, 15.9 units a month; BLDC fan about 32 watts, 9.6 units a month, at 10 hours a day.Power drawnUnits a monthHaize VX 900 mm40 W12.0Haize VX 1200 mm53 W15.9BLDC fan (Havells)32 W9.6Units = watts × 10 h × 30 days ÷ 1000 (our arithmetic)
Haize VX watts are V-Guard's published figures. The BLDC bar is Havells' "around 32 W"; V-Guard says 25–35 W. Haize 1200: 215 m³/min ÷ 53 W is about 4.06 m³/min per watt, which is what its 1-star label measures.
Normal or BLDC

What the motor changes: the bill, the inverter, the regulator

Same blades, different motor. A normal fan is cheaper to buy; a BLDC fan draws much less power and comes with a remote.

  • PowerMakers' numbers for a normal fan run from 50 W (Havells) to 70–80 W (Bajaj, Atomberg). We use the Haize's own 53 W, so the saving we show is the smaller one.
  • Inverter and low voltageA BLDC fan loads the battery less, so backup lasts longer. V-Guard and Bajaj give no hours; Atomberg claims up to 2.5 times. A normal fan slows when evening voltage falls; a BLDC fan is made to hold its speed.
  • Regulator and remoteA normal fan runs from a wall regulator. A BLDC fan comes with a remote and takes no regulator, so wire it to a plain switch.
  • When it paysUnits saved × your rate × months. At 10 hours a day one 1200 mm fan saves about 6.3 units a month; a fan that runs all day in an inverter house saves most. Weigh it against what the shop quotes extra.

Read BLDC vs normal fan, fans on inverter and what the star rating means. For battery hours see inverter backup hours; for slow fans every evening see low voltage at home.

Exhaust fans

Kitchen and bathroom: size the exhaust by the air to change

A ceiling fan only stirs the air. Steam, smoke and smell need a fan in the wall or window that sends the air out. Room volume × air changes an hour ÷ 35.3 gives m³/h. Usual practice is about 10 changes an hour for a bathroom and 15 for a kitchen. A wall and grille cut the flow roughly in half, so choose a fan with twice that air.

Where the exhaust goes
Exhaust fan in a bathroom and in a kitchen, side viewTwo side views. In the bathroom the fan sits high on the wall opposite a gap under the door, steam goes out. In the kitchen the fan sits high on the wall near the hob, steam and smoke go out.Bathroomsteam outair in under the doorKitchensmoke and steam out
Side views, simplified. Usual practice: the fan high on the wall, away from where fresh air comes in; in a kitchen as close to the hob as the wall allows.
SizePowerAir deliveryBathroom up toKitchen up to
150 mm25 W285 m³/habout 500 cubic ftabout 335 cubic ft
200 mm27 W500 m³/habout 880 cubic ftabout 590 cubic ft
250 mm27 W800 m³/habout 1,400 cubic ftabout 940 cubic ft

Power and air delivery are from Crompton's Brisk Air Neo chart (open air). Crompton labels the unit CMM, but 285 CMM from a 150 mm fan is not possible, so we read it as m³/h. The last two columns are our arithmetic (half the open-air flow, 10 and 15 changes an hour). A normal bathroom (5 × 7 ft, 9 ft high) is about 315 cubic ft. More: exhaust fan for bathroom and kitchen.

Fan box, rod and down rod
Section through a slab and ceiling fanA fan box with a U-rod cast into the slab, a canopy under the slab, a down rod hanging from it, the motor and blades, and the floor 10 feet below.slab, box cast inceiling heightfan box + roddown rodmotorbladesfloor
Side view, simplified. The box and its rod are cast into the slab; the down rod sets how low the fan hangs.
Fan box and rod

Decide the hook before the slab, the rod after

A ceiling fan hangs from a fan box cast into the slab. If the slab is already cast with no box, the fix is a fan clamp fixed to the slab by someone who knows it, not a hook in a drilled hole.

  • Before dhalaiOne fan box with rod at the middle of each fan's area, tied to the steel, with the conduit pipe running to it.
  • Down rodThe box is only the hook. The short rod in the fan's box suits ceilings up to 10 ft; add about 12 inches for 11–12 ft and 24 inches for 13–14 ft (usual practice). We order the longer rod with your fan.
  • Wiring and regulatorA normal fan takes a wall regulator and sits on the lights-and-fans MCB. A BLDC fan takes a plain switch point.

Full steps: conduit before slab casting, fan box before casting, new house wiring checklist, which MCB for which load and ceiling fan installation.

Everything we keep

Every fan and part, with its page

Each card shows what the maker publishes and whether it is on the shelf or comes by order. Ask on WhatsApp for today's price and how long an order takes.

Ceiling fans
We order it

BLDC ceiling fan with remote

Draws about 32 W, runs longer on an inverter, takes no wall regulator. V-Guard makes BLDC fans with a remote, timer and wind modes; we order the model you pick.

Today Ask rateFull pageWhatsApp
Pedestal fan
On the shelf

Finesta Neo HSP 16, 400 mm (16 inch)

Pedestal fan in black, white-blue or yellow-black. Moves from room to room: a shop counter, a veranda, a guest room. V-Guard's fans page shows no figures for it, so read the watts and RPM on the box label.

Three colours on the shelf
Today Ask rateFull pageWhatsApp
Exhaust fans
Fan box, regulator and rod

More: ceiling fans · pedestal fans · fan box with rod · Torio fan regulator · Haize vs Crompton and Havells · pedestal vs ceiling fan. Wire for the fan point: house wires.

Questions people ask us

Short answers

Which size ceiling fan for my room?

Measure in feet. Up to about 10 × 10 ft: 900 mm. About 12 × 13 ft: 1200 mm. About 14 × 16 ft: 1400 mm (Havells' room table). A bigger or long, narrow room takes two fans. The chooser above does the sum.

Is a BLDC fan worth it?

If the fan runs 8 hours or more, or the house runs fans on an inverter, yes: about 32 W against 53 W for our Haize means roughly 6 units a month saved per fan at 10 hours a day. For a spare room used an hour a day a normal fan is the better buy.

Does a BLDC fan need a regulator?

No. It comes with a remote and is wired to a plain switch. A normal fan like the Haize VX uses a wall regulator; we keep the Torio regulator.

Can you get a BLDC fan or an exhaust fan?

Yes. Every product can be ordered. Send the size and the make on WhatsApp and ask how long it takes.

Which exhaust fan for a bathroom and a kitchen?

Work out the room volume, multiply by 10 changes an hour for a bathroom or 15 for a kitchen, divide by 35.3, and pick a fan with about twice that air. A normal bathroom takes 150 mm; a kitchen with daily cooking usually 250 mm.

Is the Haize a 1-star fan, and does it matter?

Yes, V-Guard lists it as BEE 1-star. The star compares air delivered per watt: 215 m³/min ÷ 53 W is about 4.06. A BLDC or higher-star fan gives the same air for fewer watts. For a fan that runs a few hours the difference is small; for all-day use take BLDC.

Can a ceiling fan hang on a hook in the slab?

Only on a fan box cast into the slab. Without one, ask for a fan clamp fixed to the slab; see conduit before slab casting.

Where can I buy fans in Muzaffarpur?

At our store, 199 Patahi Rd (Reva Road), near Shiv Mandir, Bhagwanpur, Muzaffarpur 843113, Mon to Sat 8 am to 6 pm. We sell genuine V-Guard with a GST bill. Call or WhatsApp 90310 74624.

Sashikesh Kumar
Diploma in Electrical, Tashya Ventures

Looks after wires, switchgear, inverters and pumps at our Reva Road store, Muzaffarpur. The fan figures here are the makers' own, with the maker named; room sizes and rod lengths are marked as usual practice. Where makers disagree, the page uses the figure that makes the saving smaller.

Where the numbers come from

  1. V-Guard, Haize VX ceiling fan: 900 mm 40 W, 150 m³/min, 430 RPM; 1200 mm 53 W, 215 m³/min, 380 RPM; BEE 1-star; colours Matt Brown, Cherry Brown, Ivory, White. No warranty on the page.
  2. Havells, BLDC fan buying guide: room table 600 mm 1.2 × 2 m, 900 mm 3 × 3 m, 1200 mm 3.6 × 4 m, 1400 mm 4.2 × 4.8 m; BLDC "around 32 W", conventional "50 W or more".
  3. V-Guard, BLDC vs conventional fan: BLDC 25–35 W, conventional 50–70 W, longer inverter run, remote on its BLDC range.
  4. Crompton, Exhaust fan size chart: Brisk Air Neo 150, 200, 250 mm, 25–27 W, 285, 500, 800 air delivery (unit read as m³/h).
  5. Bajaj Electricals, BLDC fan vs normal fan, and Atomberg, BLDC fan vs normal fan: normal fan 70–80 W, BLDC 25–35 W; Atomberg's claim of up to 2.5 times longer on a battery, and 900/1200/1400 mm by room size. Both are makers selling BLDC fans, so their savings are claims.
  6. Store facts: our own shelf and bills at Rewa Road. Down-rod lengths, air changes an hour and the half-flow allowance are usual practice, not maker figures.

Tell us the room, we will tell you the fan

Send the room size in feet and the ceiling height on WhatsApp. We will name the sweep, normal or BLDC, and the rod, with today's price.

TASHYABUILDING SOLUTIONS · MUZAFFARPUR
WhatsApp 90310 74624tashyaventures.com