Water pump for your house: pick by how deep the water is and how high the tank sits
Sashikesh Kumar, Diploma in Electrical · checked against the maker pages and our pump guides, 14 Nov 2026
The short answer
Look at one number first: how far below the pump the water stands in May. Height of the house comes second. HP comes last, and more HP never pulls from deeper.
0–5 m
Self-priming pump, one of oursWater within 5 m of the pump in May. Ground floor or G+1, tank on the roof, one or two bathrooms: 0.5 HP. A taller house, a tank on a stand or three bathrooms: 1 HP.
5–7 m
Self-priming 1 HP, plate checkedThis is the edge of what any surface pump can pull. Read the suction figure on the plate, keep the pipe short and airtight.
Over 7 m
Submersible, not a bigger pumpThe pump goes down into the boring (3 inch or wider) and pushes. We can order it for you.
7 m
Pull we plan onMeasured in May or June, when water is lowest.
3 m
Push per floorPlus the tank itself; G+1 with a roof tank is about 7.5 m.
135 L
Per person, a dayIS 1172's lower figure. 150–200 L for town homes with flush toilets.
What the pump has to do in your house
Not to scale. Pull is measured from the water to the pump; push is from the pump up to the top of the tank. Bands: Crompton and V-Guard suction figures (about 6–8 m at most), with the 7 m we plan on. Floor height: usual practice.
Pick your pump
Four answers pick the pump, the HP and the head you need
Use the water level of May or June, not the day the boring was made. Your answers stay on this page.
Your pump
—
Head the pump must beat—pull + push + 10% for pipe, in metres
Water a day—at 135 L a person (IS 1172 lower figure); with showers and a western WC use 150–200 L
A working rule from our guides, not a maker's figure. Pull limit 7 m; 3 m a floor; 1.2–1.5 m for the tank; 1 m extra for every 10 m of pipe. Plate figures decide the final fit.
The three kinds
Which kind of pump, before which size
Three machines get called "motor" in Bihar. They solve three different problems.
Where each one sits
Left: sits above, pulls. Middle: hangs in the boring, pushes. Right: sits on a bathroom line, adds push. Not to scale.
We sell
Self-priming (monoblock)
Sits on the ground by the boring or sump and pulls the water up. Cheap, and any mistri can open it. Limited by pull: we plan on 7 m.
Not a way to fill the tank. It adds push on one bathroom line when the tank sits too close above the shower. Most weak taps need a 1 inch down-line instead.
Bought with the pumpSuction pipe and foot valve, a union and ball valve on the delivery side, wire and its own MCB. Foot valves, float switches, auto-starters and any pump or accessory not listed we can order; ask on WhatsApp for the time it takes. Pipe: pipe for a pump. Wire and breaker: wire size and MCB.
How much water
Per-person water decides the tank, and the pump follows the tank
A pump only has to refill what the house used. Count the people who sleep at home most nights.
People at home
At 135 L
At 150–200 L
2–3
270–405 L
300–600 L
4–5
540–675 L
600–1,000 L
6–8
810–1,080 L
900–1,600 L
135 L a person a day is IS 1172's lower figure, used for houses with a bucket bath and an Indian WC. The standard gives 150–200 L for towns of more than a lakh people with flushing toilets, so a town home with showers and a western WC should count 150–200 L. Tank sizes and why two tanks beat one big one: tank size for your family. How fast a pump fills it: 0.5 HP or 1 HP.
Which water pump is best for a house in Muzaffarpur?
Most houses here have shallow water, so a self-priming pump on the ground is the best buy: the Nova NH01 (0.5 HP) for a ground floor or G+1 house, and the Nova NF01 (1 HP) for a taller house, a tank on a stand or three or more bathrooms. If the water stands deeper than about 7 m in May, a submersible is the answer instead.
My boring is 100 feet deep. Do I need a submersible? (boring 100 feet hai, kaun sa motor)
Not necessarily. The boring's depth hardly matters for a self-priming pump; what matters is how far below the pump the water stands in May. In Muzaffarpur that is often 4–7 m. Measure it, or ask the borer where the water settled, and use the picker above.
Does a bigger HP pull water from deeper?
No. A self-priming pump pulls with air pressure, which holds up about 10.3 m of water at best, and real pumps stop well short of that. Crompton gives 7 m for its 0.5 HP pumps and about 30 feet for 1 HP. More HP pushes higher and fills faster, it does not reach deeper.
0.5 HP or 1 HP for a two-floor house?
A G+1 house with the tank on the roof, one or two bathrooms and water within 5 m is fine on 0.5 HP. A G+2 house, a tank on a stand, three or more bathrooms or a boring far from the house wants the 1 HP. If you will add a floor later, buy for the house you will have.
Do you sell submersible and pressure pumps?
We sell the Nova 0.5 HP and 1 HP self-priming pumps. Submersibles and pressure (booster) pumps we can order for you; ask on WhatsApp for the time it takes, and send your boring width, water depth and floors.
How many litres of water does one person need?
135 litres a person a day is IS 1172's lower figure, enough for a bucket bath and an Indian WC. Town homes with showers and a flush toilet should count 150–200 litres. A family of five at 135 L is about 675 litres a day.
Why is the water weak in my top-floor shower even though the pump runs?
The pump fills the tank; the tank's height above the tap gives the push, and it is small. First check the down-line (1 inch), the shower face for iron grit and the tank stand. A booster is for a shower too close below the tank; see the pressure pump guide.
Sashikesh Kumar
Diploma in Electrical, Tashya Ventures
Looks after wiring, MCBs, fans, inverters and pumps at our Reva Road store, Muzaffarpur. The depth bands and pull limits here are the makers' own figures, named below and checked on 14 Nov 2026. The 7 m we plan on, 3 m a floor and the 10% pipe allowance are our working rules and are labelled.
Where the numbers come from
Crompton, 0.5 HP and 1 HP water pumps: suction up to 7.0 m for 0.5 HP, up to 30 feet for 1 HP.
V-Guard, buying guide for water pumps: normal self-prime pumps about 6 m; shallow-well pumps up to 8 m; tube-well submersibles for 3, 3.5 and 4 inch borings.
Taro (Texmo), monoblock buyer's guide: a monoblock is not for a suction head above 20 feet; domestic monoblocks run about 0.5–2 HP.
Crompton, centrifugal vs submersible: surface pumps are limited by suction lift; a submersible avoids it.
CGWB, Muzaffarpur district profile: depth to water 2.09–7.63 m before the monsoon, 0.67–5.21 m after (2011 readings).
IS 1172:1993, clauses 4.1 and 4.1.1: 150–200 litres a head a day for towns above one lakh with full flushing, 135 for smaller houses.
Standard figures: air pressure holds up about 10.3 m of water at sea level. Our working rules (7 m pull, 3 m a floor, 1.2–1.5 m tank, 10% pipe) and the choosing rule above are usual practice, worked out in 0.5 HP or 1 HP.
Tell us your water depth and floors
We will tell you which pump fits, with the price for the day, on WhatsApp.