Nova NF01 1 HP self-priming pump in Muzaffarpur: for a taller house or a long run, with the wire to match

The short answer

The Nova NF01 is our 1 HP pump for a taller house, a tank up on a stand, a long pipe run or three or more bathrooms. It is a single-phase self-priming pump: it stands on the ground and pulls water from a boring, sump or tank. A bigger motor pushes harder and fills faster; it does not pull from deeper. Plan on 7 m in summer, exactly as for the 0.5 HP, and take a submersible beyond that. Today's price is in the price list below, with GST on the bill.

7 m
Pull we plan onMeasured in May or June, when the water is lowest. Same as the 0.5 HP.
Plate
Nova figures: read the nameplateNova has not published suction, head or flow for the NF01 where we could find it.
2.5 · 16
sq mm wire, 16 A C-curve MCBOn its own line. Use 4 sq mm wire if the pump is far from the board.

The rule for choosing, with floors, bathrooms and fill time worked out, is in 0.5 HP or 1 HP. Water deeper than 7 m: self-priming or submersible. Smaller house: Nova NH01, 0.5 HP.

The pump, part by part
Parts of a monoblock self-priming pumpA motor on the left, the pump casing on the right. Water comes in through the suction pipe on the right and leaves through the delivery pipe on top. A priming port on the casing is filled with water before the first start. The terminal box takes the wire; the nameplate is on the motor. DELIVERY up to the tank Priming port fill with water SUCTION from the boring Terminal box the wire goes in here NAMEPLATE Every figure you need is on the plate
The usual layout of a monoblock pump. Where each port sits on your pump is marked by the arrows on its casing, and the nameplate is on the motor.
Is it for you

Take the 1 HP when height, run or bathrooms ask for it

The figures for each case are on the 0.5 or 1 HP guide. Here is the short version.

Nova NF01 · 1 HP

A taller house or a longer run

Tank on a stand or two floors up, a long pipe along the ground, three or more bathrooms, or water 5–7 m down in summer, where the extra power keeps a margin.

0.5 HP instead

A ground or G+1 house

Tank on the roof, shallow water, one or two bathrooms. Cheaper to buy and to run: Nova NH01.

Neither

Water deeper than about 7 m

No self-priming pump of any HP pulls that reliably. You need a submersible. We can order one; ask on WhatsApp for the time it takes. Start from self-priming or submersible.

A pump that is too big does not fix a leaking suction pipe or a weak supply. If you are unsure, send us your floors, tank position and water depth: pump picker.

Reading the nameplate
Nameplate lines and what each is forSix lines to read on the plate: suction lift, total head, flow, input watts and amps, volts, and port sizes. Each line has a note on what to compare it with. NAMEPLATE: WRITE THE FIGURES Suction lift (m) Against your boring in May–June; we plan on 7 m Total head (m) Against the push to the tank top plus pipe Flow (litres per minute) How fast the tank fills Input (watts and amps) Amps pick the wire: up to 12 A is 2.5 sq mm Volts · single phase Your evening voltage must sit inside this range Ports (inch) Suction and delivery pipe size
Write each figure in the dotted space when you read the plate, then send us the photo.
The nameplate

Nova's figures are not published, so read the plate

We could not find a Nova datasheet for the NF01, so this page prints no suction, head or flow figure for it. The plate on the motor carries them for the pump you are actually given, and that is the figure to trust. Read it at the shop and again when the pump is fitted.

Two lines matter most. Suction lift against your boring's summer depth: if the plate says less than your water needs, the pump will run and lift nothing. Amps against your wire, next section.

A 1 HP motor is rated 746 W at the shaft; the plate shows what it takes from the supply, which is more. For what that means on the bill, see the 0.5 or 1 HP guide.

Send a photo of the plate on WhatsApp, with your water depth and floors, before the pipe goes in. We will look at it with you.

From the board to the pump
Wiring chain for the pumpFrom the distribution board, a 16 A C-curve MCB on its own line, then 2.5 sq mm copper with three cores to the pump. If the pump is far from the board, the wire becomes 4 sq mm. Board its own way 16 A C-curve MCB never 20 A on 2.5 sq mm 2.5 sq mm copper phase · neutral · earth Nova NF01 terminal box FAR AWAY? 4 sq mm MCB stays 16 A
The wire changes with distance; the MCB does not.
Wire and MCB

2.5 sq mm and a 16 A C-curve, 4 sq mm if far

The plate's amps decide the wire. Up to 12 A: 2.5 sq mm copper, three cores (phase, neutral and earth), with a 16 A C-curve MCB. In a wall pipe 2.5 sq mm carries 18 A (V-Guard Classo+ table), so a 16 A breaker protects it; a 20 A breaker would let through more than the wire can carry. The earth wire is the same size as the phase (IS 732).

If the pump is far from the board, more than about 25 m, use 4 sq mm so the voltage does not sag at the pump. The MCB stays 16 A. If the plate shows more than 12 A, send us a photo of it before you buy the wire.

Give the pump its own MCB and switch, not a socket shared with an iron. Why C-curve, and the other loads: which MCB for which load and wire amps chart. Low voltage in the evening: low voltage.

First start

Three things that decide whether it pulls water

Prime it

  1. Fill the casing with clean water through the priming port until it overflows.
  2. Close the port tight.
  3. Check the foot valve at the end of the suction pipe is well under the water, off the bottom.
  4. Switch on. Water should reach the tank in a few minutes.
  5. If it does not, switch off and prime again. Do not let it run dry.
Usual practice. The manual in the box has the exact steps for your pump.

Short, straight, airtight suction pipe

A small air leak at a joint on the suction side is the commonest reason a good pump will not lift. Keep the pipe short, rising slowly, with no loop that traps air. The foot valve holds the water in the pipe so the pump stays primed. Pipe size follows the port size on the plate:

Prices are from our latest bill and change often. Please confirm today's rate on WhatsApp or call before buying.

pipe for a pump.

Never run it dry

A pump with no water inside overheats and ruins the shaft seal. If water has not come in a few minutes, stop and look for the air leak. A float switch for the tank or an auto-starter saves you walking to the switch; we can order both.

We sell · we can order

The pump and what goes with it

Today's price for each is posted at the store and on WhatsApp, with a GST bill. We sell genuine Nova.

Foot valves, float switches, auto-starters and any pump size not listed we can order for you; ask on WhatsApp for the time it takes.

Warranty and service

The pump comes with the maker's warranty card. Keep the card and our GST bill. If something goes wrong, bring the pump, the card and the bill to our Rewa Road store and we send it to the company. The length of the warranty is printed on the card; we do not quote one here because Nova's terms are on its card and not on a page we could read.

Questions people ask us

Short answers

What is the price of a Nova 1 HP pump in Muzaffarpur?

Our price for the day is posted at the Rewa Road store and sent on WhatsApp, with a GST bill. Prices change with the day and the carriage, so we do not quote one from memory.

How deep can the Nova NF01 pull water?

Nova has not published a suction figure for it, so read the plate. We plan on 7 m, measured in summer, for any self-priming pump; air pressure stops all of them at about 10 m. Deeper than 7 m, use a submersible. See self-priming or submersible.

What wire and MCB for a 1 HP pump?

2.5 sq mm copper, three cores, and a 16 A C-curve MCB on its own line, when the plate shows up to 12 A. Use 4 sq mm if the pump is far from the board (more than about 25 m). Over 12 A on the plate, send us a photo.

Does a 1 HP pump use more current than a 0.5 HP?

Yes, about double while running, but it fills the tank in about half the time. The worked figures are in 0.5 HP or 1 HP.

Can I run it on an inverter?

A motor pulls a jolt for a moment at start, and that is what trips small inverters. Check inverter size first.

Is it single phase?

Yes. It runs on the normal house supply; it does not need a three-phase connection.

I need a different size or model.

We can order it for you. Ask on WhatsApp for the time it takes.

Sashikesh Kumar
Diploma in Electrical, Tashya Ventures

Looks after wiring, MCBs, fans, inverters and pumps at our Reva Road store, Muzaffarpur. Nova's own figures for the NF01 are not published, so this page gives none and sends you to the nameplate. The wire rule is V-Guard's table and IS 732; the first-start steps are usual practice and labelled so.

Where the numbers come from

  1. Nova NF01: no maker page or datasheet found on 13 Nov 2026. Suction, head, flow, watts and amps are therefore not printed; read the nameplate.
  2. V-Guard, Classo+ cable table: 2.5 sq mm in a wall pipe carries 18 A, so a 16 A MCB. Earth wire the same size as phase (IS 732).
  3. Crompton, 1 HP water pump: suction up to 30 feet on its own 1 HP pumps, quoted only as a comparison, not as a Nova figure. We plan on 7 m.
  4. Our own guides for the pull and push, fill time, MCB and wire: 0.5 HP or 1 HP, self-priming or submersible.
  5. Store facts: what we sell at Rewa Road.

Send us your house

Floors, where the tank sits, how deep the water stood, and a photo of the nameplate. Sashikesh will say if the NF01 is right, and send the list of wire, MCB and pipe with today's price.