हिंदी Call90310 74624
Home›Guides›Pumps
Pump guide · choosing the size

0.5 HP or 1 HP pump for your house: work out the height first

The short answer
  • 0.5 HPGround or ground-plus-one, tank on the roofWater within about 5 m below the pump in summer, one or two bathrooms. Nova NH01
  • 1 HPTaller house, tank on a stand, long pipe runOr three bathrooms and more, or water 5–7 m down in summer. Nova NF01
  • NeitherWater deeper than about 7 m in summerNo surface pump pulls that reliably, whatever its HP. You need a submersible.

HP is the motor's power. What decides the pump is how far it pulls water up from below and how high it pushes it to the tank. A bigger motor pushes higher and faster. It does not pull from much deeper.

7 m
Pull limit we plan forCrompton: 7.0 m for its 0.5 HP pumps, "30 feet" for 1 HP. Physics stops all at about 10 m.
3 m
Per floor of pushPlus the tank's own height. A G+1 house with a roof tank is about 7.5 m.
≈ same
Units per tank1 HP draws double but fills in about half the time. Worked below.
What the pump has to do
Pull and push for a ground-plus-one house A pump at ground level beside a boring. Below it, water stands 6 m down: that is the pull. Above it, the delivery pipe climbs two floors of 3 m each and the 1.4 m tank on the roof: that is the push, about 7.4 m. The pull limit of 7 m for a 0.5 HP pump, about 9 m claimed for 1 HP, and the 10.3 m physical limit are marked on the ruler. water level in May 1st floor ground TANK foot valve PUMP 03 m6 m3 m6 m 7 m · 0.5 HP limit ≈ 9 m · 1 HP claim 10.3 m · physics, all pumps PUSH ≈ 7.4 m PULL 6 m Total head 7.4 + 6 + pipe ≈ 15 m for this house
Drawn to scale, 1 m = 25 px. Pull limits: Crompton's 0.5 HP and 1 HP pump pages. The 10.3 m line is atmospheric pressure, a standard figure; real pumps stop well short of it.
Count your height

Three numbers, added together

Every pump maker prints a "head": the total height it can lift water. Yours is the pull below the pump, the push above it, and a little for the pipe.

1Pull: water to pump

≤ 7 m

From the water surface up to the pump, in May or June, when the water is lowest. A self-priming pump only makes a vacuum; air pressure pushes the water up the pipe, and that pressure equals about 10.3 m of water. Crompton gives 7.0 m for its 0.5 HP pumps and "up to 30 feet" for 1 HP. Kirloskar lists 3 m for priming without a foot valve. We plan for 7 m with either size.

2Push: pump to tank top

3 m a floor

Count floors at about 3 m each (usual practice), then add the tank stand and the tank itself, about 1.2–1.5 m for a 1000 litre tank. Ground floor with a roof tank: about 4.5 m. G+1: about 7.5 m. G+2: about 10.5 m. A tank on a 5 ft stand adds 1.5 m.

3Pipe: run and bends

+10%

Water rubbing along the pipe and turning at each elbow costs height, as if the tank were higher. For a 1 inch pipe, add about 1 m for every 10 m of pipe, counting the pull, the push and any run along the ground (our working rule). A boring 15 m away from the house adds 1.5 m.

Muzaffarpur's water is shallow, but it moves. CGWB's district profile recorded the water at 2.1–7.6 m below ground before the monsoon and 0.7–5.2 m after it, and its August 2025 bulletin noted falls of more than 2 m in parts of the district between May and August. So a boring that is 4 m in October can be 6–7 m in May, right at the limit. Ask your boring mistri what depth the water stood at when it was drilled, and add 2 m for summer. Full detail: how deep a self-priming pump can pull.

Which pump for which house

Pull first, then push, then bathrooms

Both of our pumps can reach a roof tank on most houses in Muzaffarpur. The real difference is how deep the water is, how fast the tank fills and how long the pipe runs.

Your houseChooseWhy
Ground floor, roof tank, water within 5 m in summer0.5 HPTotal head about 10–12 m. Crompton's 0.5 HP pumps work to 20–30 m.
G+1, roof tank, water within 5 m, 1–2 bathrooms0.5 HPTotal head about 13–15 m. A 1000 L tank fills in about half an hour.
G+1 with 3+ bathrooms, or a tank on a stand1 HPMore water a day and more height; the 1 HP fills about twice as fast.
G+2, or a boring far from the house1 HPTotal head 18 m and up, where a 0.5 HP slows down sharply.
Water 5–7 m below the pump in summer1 HPClose to the pull limit; the 1 HP keeps a little margin.Crompton: 7.0 m (0.5 HP) against 30 ft (1 HP)
Water more than 7 m down in summerSubmersibleNo self-priming pump of any HP pulls this reliably.
Building the first floor later?Buy for the house you will have, not the one you have now. A 0.5 HP bought for the ground floor is often too slow once the tank moves up a floor. See the pump for a 2-storey house. A weak shower on the top floor is a different problem, cured by a pressure pump on that bathroom's line, not a bigger tank-filling pump.
Three questions
Choosing between 0.5 HP, 1 HP and a submersible First: how far below the pump is the water in summer? More than 7 m: submersible. 5 to 7 m: 1 HP. Within 5 m: next question. How high is the tank top above the pump? More than 8 m, or a long pipe run: 1 HP. Up to 8 m: next question. How many bathrooms? Three or more: 1 HP. One or two: 0.5 HP. Water below the pump, in May–June? over 7 m within 5 m 5–7 m SUBMERSIBLE 1 HP Tank top above the pump? up to 8 m over 8 m, long run 1 HP Bathrooms in the house? 1 or 2 3 or more 0.5 HP 1 HP Nova NH01 Nova NF01 up to 8 m: a G+1 house with a 1000 L tank on the roof
Our working rule for houses in Muzaffarpur, built on the makers' pull limits and head ranges. The calculator further down does the same sum with your own numbers.
Fill time and the electricity bill

The 1 HP draws double, and fills in about half the time

A 1 HP motor is rated 0.75 kW, a 0.5 HP 0.37 kW. But the meter counts power multiplied by time, and the bigger pump runs for much less time. Per tank, the units come out close.

Total head0.5 HP1 HP
10 mground floor, shallow water27 min0.16 units16 min0.20 units
18 mG+1 with deeper water, or G+238 min0.23 units19 min0.24 units
26 mnear the 0.5 HP's limit64 min0.40 units24 min0.29 units

To fill one 1000 litre tank. Worked from Crompton's published ranges for one matched pair: Mini Master II (0.5 HP, 600–2600 litres an hour over 6–30 m) and Mini Master I (1 HP, 950–4000 litres an hour over 6–48 m), read in a straight line between the two ends. Units at the motor's rated power; the meter reads a little more for both, since no motor is fully efficient. Your Nova pump's figures are on its nameplate.

What this means for your billA family of five uses about 675 litres a day (135 litres per person, IS 1172's lower figure; it gives 150–200 with full flushing). At 18 m that is about 5 units a month with either pump. The bill does not decide this choice. Time does: the 0.5 HP must run twice as long, and at heights near its limit it runs so long that it costs more and heats up.
Minutes to fill a 1000 L tank
Fill time at three heights At 10 m: 0.5 HP 27 minutes, 1 HP 16. At 18 m: 0.5 HP 38, 1 HP 19. At 26 m: 0.5 HP 64, 1 HP 24. 020406080 min 10 m18 m26 m 27 · 0.5 HP 16 · 1 HP 38 · 0.5 HP 19 · 1 HP 64 · 0.5 HP 24 · 1 HP
Rough figures from Crompton's published flow and head ranges, for comparison only. The gap widens as the height grows.
Wire, MCB and voltage

Same wire for both, on the pump's own line

Wire: 2.5 sq mm, three cores

Phase, neutral and earth, all 2.5 sq mm copper, for both the 0.5 HP and the 1 HP on a normal house run. V-Guard's Classo+ table gives this size 18 A inside a wall pipe, far above what either pump draws while running. Earth wire the same size as phase (IS 732).

Read the amps on the nameplate. Up to 12 A is this size. If the pump sits more than about 25 m from the board, send us the distance and we will check the voltage drop.

MCB: 16 A, C-curve

A motor pulls a jolt of 2 to 3 times its running current for a moment as it starts. A B-curve MCB can trip on that jolt; a C-curve rides through it. 16 A, never 20 A, on 2.5 sq mm wire. Give the pump its own MCB and switch, not a socket shared with the iron.

Low voltage in the evening

Crompton rates its home pumps for 180–260 V. Below that, any motor runs hot and slow, and the 1 HP feels it more because it draws more current. If your voltage drops in the evening, fill the tank in the morning, and see low voltage before blaming the pump.

Running the pump on an inverter? Check inverter size first: a motor's starting jolt is what trips small inverters.
What goes wrong

Four mistakes we see after a pump is bought

TOO HIGH

Pump fitted up high

You see: it hums, no water comes

Every metre the pump sits above the water is pull. Put it at ground level, as close to the water as you can, with a short straight suction pipe.

1 MM OLD WIRE

1 HP on the old thin wire

You see: warm switch, MCB trips, burnt plug

The 1 HP draws about twice the current. Run 2.5 sq mm on its own C-curve MCB. A loose plug top on a pump line is where fires start.

OCTOBER MAY: −2 m

Water depth measured after the rains

You see: fine all winter, dry in May

Muzaffarpur's water level can fall 2 m or more by summer (CGWB). Size the pump for May, not October.

AIR GETS IN

A leaky joint on the suction side

You see: runs, but water comes in spurts

The suction pipe works under vacuum, so a loose joint sucks air instead of dripping water. Teflon on every thread, solvent on every UPVC joint, and a good foot valve at the bottom.

Work it out for your house

Your pull, push and fill time

Put in your house. The sum is the one above: pull, push, and 10% of the pipe for friction. Fill times use the Crompton pair from the table, so read them as a rough guide.

Pull — m · push — m · pipe — m
Total head — m

Your pump

—
—
0.5 HP, per 1000 L tank——
1 HP, per 1000 L tank——
Send this to us on WhatsApp

Daily water at 135 litres a person (IS 1172's lower figure; 150–200 with full flushing). Price of each pump: Ask rate, filled in from today's rate. The full pump picker adds pipe size and fittings.

Questions people ask us

Short answers

Which is better for home, 0.5 HP or 1 HP pump?

The one that fits your height. A one-floor or ground-plus-one house with the tank on the roof, water within about 5 m below the pump in summer and one or two bathrooms is well served by 0.5 HP. A taller house, a tank on a stand, a long pipe run, three or more bathrooms, or water 5 to 7 m down in summer needs 1 HP. Deeper than about 7 m, neither: use a submersible.

Is a 0.5 HP pump enough for a two-storey house? (do manzil ke liye aadha HP chalega?)

Often yes, if the tank sits on the roof of the first floor and the water is shallow. That is about 7.5 m of push plus a few metres of pull, well inside the 20 to 30 m head Crompton gives for its 0.5 HP pumps. It fills a 1000 litre tank in roughly half an hour. With the tank on a stand, a second floor, or water lower than 5 m in summer, take 1 HP.

How deep can a 1 HP pump pull water? (1 HP motor kitne feet se kheenchega?)

Crompton says up to 30 feet (about 9 m) on its 1 HP page and up to 7.0 m on its 0.5 HP pages. No surface pump can beat about 10 m, because air pressure is what pushes the water up the suction pipe. We plan for 7 m for both sizes, measured in summer. Beyond that, use a submersible.

Does a 1 HP pump use a lot of electricity?

It draws about twice the power while running (0.75 kW against 0.37 kW), but it fills the tank in about half the time. Per tank the units come out close: about 0.23 against 0.24 units for a 1000 litre tank 18 m up, worked from Crompton's published ranges. When the height is near the small pump's limit, the 0.5 HP runs so long that it uses more.

What wire and switch does a 1 HP pump need?

For a normal house run, 2.5 sq mm copper wire for phase, neutral and earth, and a 16 A C-curve MCB on its own line, the same as for a 0.5 HP. Read the amps on the nameplate: up to 12 A is this size. If the pump is far from the board, send us the distance.

What if my boring is very deep?

If the water stands more than about 7 m below the pump in May or June, no self-priming pump of any HP will pull it reliably. You need a submersible pump that sits down in the water and pushes it up. A bigger self-priming pump does not solve it. Start from self-priming or submersible.

Should I take 1.5 HP for a two-floor house?

Not for filling a roof tank. A 1 HP self-priming pump is rated to well over 40 m of head, and a ground-plus-two house with the tank on the roof needs about 12 to 20 m. A bigger motor adds current and cost, and does not pull from any deeper.

Can my tank-filling pump also give pressure to the shower?

No. It has no switch to stop when the tap closes. For a weak top-floor shower you need a small booster on that bathroom's line: see pressure pump for home.

Sashikesh Kumar
Diploma in Electrical, Tashya Ventures

Looks after wiring, MCBs, fans, inverters and pumps at our Reva Road store, Muzaffarpur. The pump figures on this page were checked against Crompton's and Kirloskar's published figures and CGWB's Muzaffarpur data on 13 Nov 2026. Floor heights, pipe allowance and the choosing rule are usual practice and labelled so.

Where the numbers come from

  1. Crompton, 0.5 HP water pumps: suction up to 7.0 m; head about 20–30 m; 30–40 litres a minute; for shallow sources.
  2. Crompton, 1 HP water pumps: suction up to 30 feet, delivery to about 150 feet; 1 HP for higher flow and deeper lift.
  3. Crompton, Mini Master I: 1 HP, 0.75 kW, 950–4000 litres an hour, 180–260 V. Head range 6–48 m and the Mini Master II (0.5 HP, 0.37 kW, 6–30 m, 600–2600 litres an hour) as listed on Moglix.
  4. Crompton, Glide Plus II: 0.37 kW, suction up to 7.0 m, maximum lift 21 m, 180–260 V.
  5. Kirloskar Mini 40S, listing: primes up to 3 m static suction without a foot valve.
  6. CGWB, Muzaffarpur district profile: depth to water 2.09–7.63 m before the monsoon, 0.67–5.21 m after (2011).
  7. CGWB, Bihar water level bulletin, August 2025: falls of more than 2 m in parts of Muzaffarpur, May to August 2025.
  8. Standard figures: 1 HP = 746 W; atmospheric pressure at sea level ≈ 10.3 m of water; 135 litres per person a day (IS 1172's lower figure; 150–200 with full flushing).
  9. Wire and MCB rule: V-Guard Classo+ table (2.5 sq mm in a wall pipe carries 18 A, so a 16 A MCB); motor starting current 2–3 times running (V-Guard sizing guide); earth same size as phase (IS 732).
  10. Fill times: worked by us from source 3, in a straight line between the published ends of each range. Floor height, tank height, pipe allowance and the choosing rule: usual practice.

Tell us your house

Floors, where the tank sits, and how deep the water stood in the boring. Sashikesh will pick the pump and send the list of pipe, wire and fittings with today's price.

TASHYABUILDING SOLUTIONS · MUZAFFARPUR
WhatsApp 90310 74624tashyaventures.com