Pipes and fittings in Muzaffarpur: which pipe for which job, and which size

The short answer

A house needs three kinds of pipe, one for each kind of water. Cold supply is UPVC. Hot water is CPVC. Drains are SWR. Never swap them.

UPVCCold water, 5–60 °CTank to taps. ½″, ¾″, 1″, 1½″. PVC solvent cement.
CPVCHot and cold, up to 82 °CGeyser to every hot tap and shower. CPVC solvent only.
SWRDrains, no pressureToilet 110 mm (4″), floor and basin waste often 75 mm. Rubber ring or solvent.
1 → ½″
Size steps down1½″ tank, 1″ down-line, ¾″ bathroom, ½″ tap.
82 °C
CPVC limitPrince's sheet; Ashirvad says 93 °C. We use the lower.
Any size
Can be orderedIf it is not on the rack, we order it. Ask on WhatsApp for the time.
Three pipes in one house
Roof tank Geyser WC Septic tank 1½″ outlet, valve ¾″ branch 1″ down-line, ¾″ branch 110 mm stack cowl CPVC hot Cold: UPVC Hot: CPVC Drain: SWR
Schematic, not to scale. Blue is the cold line, red the hot line, grey the drain. The drain stack ends above the roof under a cowl.
Pick by job

What are you plumbing? Tap the job.

You get the pipe, the size, how it is joined and what to ask for. Nothing here is a price; the rate is one tap away.

Which size

The pipe gets thinner as it feeds fewer taps

UPVC sizes, outside diameter to scale
1½″tank outlet, pump line1″main down-line¾″each bathroom, the kitchen½″the last run to each tap
Outside diameters from Prince's Easyfit table: 48.26, 33.40, 26.67 and 21.34 mm. Sizes are the same on a Prince or Ashirvad UPVC pipe.

Water in a roof tank has only its height to push it, about 1 kg/cm² for every 10 m. So the thick pipe sits at the tank, where the whole house draws, and the thin pipe sits at the tap, where one tap draws. Never run ½″ from the tank, and never feed a whole bathroom on ½″.

Hot water follows the same steps but in CPVC: ½″ to the shower and basin, ¾″ for a hot branch. CPVC has its own size system, so a ¾″ CPVC does not fit a ¾″ UPVC fitting without an adaptor.

When a top-floor bathroom, a long branch or four bathrooms ask for a size up, the pipe-size guide says so: pipe size from tank to bathroom. For the pump's line: which pipe for the pump. Tank size: what overhead tank for your family.

Joints

Each pipe has its own glue

The wrong cement is the commonest reason a new line leaks. Check this table before you buy the tin.

PipeJoined withWhere threads are used
UPVCCold supplyPVC solvent cement (we keep Pipefix 101 and Hold)MTA and FTA with Teflon tape, only where a tap, valve or tank screws in. A threaded joint holds half the pressure (Prince).
CPVCHot and coldCPVC solvent cement only (we keep Truzo CPVC, 100 ml). PVC cement does not do this job.CPVC MTA at the tap or geyser, with tape. Our ¾×½ CPVC MTA also steps the size down.
SWRDrainsRubber ring (push-fit) or solvent. The ISI tee with door, bend with door and P-trap we keep are ring fit.None. Drains carry no pressure; they need a steady fall.

How to make the joint: how to join CPVC pipe (the same cut, chamfer, brush and wait steps apply to UPVC). A joint that drips: water dripping from a pipe joint.

Our shelf

The product groups, each with its own page

We sell genuine Prince and Ashirvad with a GST bill. Where a size is not on the rack today, we order it; send a message and we tell you how long it takes. Pages still going up are linked by address and open as they are published.

UPVC pipes and fittings

Cold water · ½″ to 1½″

The standard cold supply: tank, down-line, bathroom branches and taps.

On the rack
  • Ashirvad UPVC pipe in ½″ and 1″
  • Prince UPVC fittings ½″ to 1½″: ball valve, tee, elbow, tank nipple, MTA, bush, reducing tee, reducing elbow and socket
UPVC page

Prices are from our latest bill and change often. Please confirm today's rate on WhatsApp or call before buying.

1″ pipeAsk today's rateper length

Prince Easyfit, Sch 40 and Sch 80

Lead-free UPVC · 5–60 °C

Prince's own UPVC system: thin-wall Sch 40 pipe, heavier Sch 80 fittings at the weak points.

On the rack
  • Easyfit Sch 40 pipe, 3 m lengths
  • Sch 80 elbow, FT elbow with metal insert, MTA, FTA, union, coupler, reducer, end cap, reducing tee
Easyfit pagePrinceAsk today's rateper length

CPVC pipes and fittings

Hot and cold · geyser lines

Anything a geyser feeds: shower, basin, kitchen hot tap. Joined only with CPVC solvent.

On the rack
  • CPVC MTA ¾×½ and Truzo CPVC solvent
  • CPVC pipe and fittings in ½″, ¾″ and larger: we order Prince SmartFit Plus for you
CPVC pageCPVC sizesAsk today's rateper length

SWR drainage pipes

Soil, waste and rain · 110 mm (4″)

Toilet, floor trap and roof water out of the house, to the septic tank or nali.

On the rack
  • 110 mm single tee, single tee with door (ISI, ring fit), bend with door
  • P-trap 125×110 mm, 4″ cowl, 4″ aluminium clamp
SWR page110 mm pipeP-trapCowl and clampAsk today's rateper length

Casing pipe for boring

Ashirvad 4″ · IS 12818

Lines a borewell so the hole does not collapse and sand stays out. Not a supply pipe.

On the rack
  • Ashirvad 4″ casing pipe
  • Other classes, slotted and ribbed: ordered for your depth
Casing pageAshirvadAsk today's rateper length

GI pipes and fittings

Galvanised iron · at the pump

A short rigid piece at the pump outlet and the tank, or repair in an old house. Not for new house lines.

On the rack
  • 1½″ GI elbow
  • GI pipe and other GI fittings: we order them; ask on WhatsApp
GI pageAsk today's rateper piece

Solvents and tapes

PVC cement, CPVC cement, Teflon

The tin that joins the pipe, and the tape that seals a thread. Buy it with the pipe.

On the rack
  • PVC solvent: Pipefix 101, Hold
  • CPVC solvent: Truzo, 100 ml · Teflon tape
Solvents pageAsk today's rateper tin

Today's price for every size and length: pipe rates. Brands: Prince Pipes (Easyfit UPVC, SmartFit Plus CPVC, Ultrafit SWR), Ashirvad by Aliaxis (Aqualife+ UPVC, FlowGuard Plus CPVC, casing). Side by side: Prince vs Ashirvad. Plumbers: register with us.

Order

Send one line before you travel

Category, size, schedule, joint type and quantity, or a photo of the marking on the old pipe. We reply with what is on the rack and, for anything else, how long the order takes.

Send on WhatsApp
Questions people ask us

Short answers

Which pipe do I use for hot water, and which for cold?

CPVC for anything a geyser feeds, UPVC for cold lines. Prince rates Easyfit UPVC for water from 5 to 60 °C, which is too low for geyser water. Prince rates its SmartFit Plus CPVC to 82 °C (Ashirvad says 93 °C for its own CPVC; we go by the lower figure). The full comparison is on CPVC vs UPVC vs PVC vs GI.

Are PVC, UPVC and "ASTM pipe" the same thing?

In shop talk, yes: all are rigid PVC pipe. For water supply in a house you want UPVC (unplasticised PVC) pressure pipe, and Prince makes it as Easyfit. Drain pipe (SWR) and borewell casing are also PVC-based, but they are made for different jobs and do not carry water under pressure.

What size pipe for the house?

The usual two-storey house runs 1½″ at the tank outlet, 1″ for the down-line, ¾″ to each bathroom and the kitchen, and ½″ to each tap. The drawing above shows it; pipe size from tank to bathroom says when to go one size up.

Is the 4 inch pipe the same as 110 mm?

Yes. The toilet line is 110 mm outside diameter, which shops call 4 inch. Bathroom floor and basin waste is often 75 mm; ask us and we will match it to your drawing.

Can I use UPVC fittings on CPVC pipe?

No, not directly. CPVC uses a different size system (½″ CPVC is about 15.9 mm outside, ½″ UPVC is 21.3 mm) and a different solvent cement. A threaded adaptor, like our ¾×½ CPVC MTA, is how the two meet at a tap or a valve.

You do not show my size. Can you get it?

Yes. Every pipe, fitting and size can be ordered. Send the category, size, schedule, joint type and quantity on WhatsApp, or a photo of the marking printed on the old pipe, and we reply with the time it will take.

What is the price of UPVC pipe in Muzaffarpur?

Pipe prices move with the maker's list, so they are on the pipe rate board, dated each morning, with GST on the bill. The cards below show "Ask rate" until you open the rate for your size.

Arun Tiwari
Thekedar · site work, costs and plumbing, Tashya Ventures

Twenty years on sites around Muzaffarpur. Temperatures and sizes here are from the Prince and Ashirvad product pages, checked on 14 Nov 2026; where the makers differ, the page says so and takes the safer figure.

Where the numbers come from

  1. Prince Pipes, Easyfit UPVC page: lead-free, 5–60 °C, outside diameters, threaded joint at half the rating.
  2. Prince Pipes, SmartFit Plus CPVC page: up to 82 °C. Ashirvad, FlowGuard Plus CPVC page: up to 93 °C.
  3. Prince Pipes, Ultrafit SWR page: building drainage, ring or solvent fittings. Ashirvad, casing pipes page: IS 12818.
  4. ASTM D2846 (CPVC hot and cold water, CTS sizes): ½″ CTS is 15.9 mm outside. Standard figure. About 1 kg/cm² per 10 m of water height: standard figure.