Pipe fittings A to Z: what each one is, where it goes, and what we keep

The short answer

A fitting is the part between two pipes: it turns them, splits them, joins them, shrinks them or ends them. Your plumber's list is a list of these, with sizes. Below, each one is drawn, explained in a line, and matched to what is on our rack, so you can check the list before the bill.

Read a name from the back: the size comes last (25×15 is a 1″ main with a ½″ branch), the shape is in the middle (reducing tee), and Sch 80 or UPVC at the front tells the wall and the material.

15 mm = ½″
Sizes in mm and inches20 = ¾″, 25 = 1″, 32 = 1¼″, 40 = 1½″, 50 = 2″.
Sch 80
The heavier fittingSch 40 fitting ½″: 25.30 kg/cm². Sch 80: 35.85 (Prince).
Any size
Can be orderedNot on the rack? We order it. Ask on WhatsApp for the time.
One cold line, eight fittings
Roof tank 1 2 3 4 5 6 7 8 1½″ line1″ down-line½″ branchtap
Schematic, not to scale. 1 tank nipple, 2 ball valve, 3 union, 4 reducer 40×25, 5 elbow, 6 reducing tee 25×15, 7 FT elbow with metal insert, 8 threaded adapter (MTA) at the tap. Sizes step down from 1½″ to ½″.
Read the list

How to read one line of a plumber's list

Take the line "Sch 80 UPVC reducing tee 25×15". It has four pieces of information.

Sch 80The wall thickness. Sch 80 is the heavier wall; Sch 40 is the lighter. We keep Sch 80 fittings at the weak points.
UPVCThe material: cold water. CPVC is for hot, GI is iron, SWR is for drains.
Reducing teeThe shape: a tee whose branch is smaller than the main.
25×15The sizes in mm: 25 mm main (1″), 15 mm branch (½″).
Name in mmIn inchesPipe outside diameter, UPVC (Prince)
15 mm½″21.34 mm
20 mm¾″26.67 mm
25 mm1″33.40 mm
32 mm1¼″42.16 mm
40 mm1½″48.26 mm
50 mm2″60.32 mm

CPVC has its own size system: a ½″ CPVC pipe is 15.9 mm outside, so a CPVC pipe and a UPVC fitting of the same name do not match. They meet through a threaded adapter, not by solvent. More on CPVC vs UPVC vs PVC vs GI.

In a bathroom line

Where each fitting goes, from tank to tap

The drawing above, in words. Pipe sizes for each step: pipe size from tank to bathroom.

SpotFittingWhy
Tank outletTank nipple, ball valve, unionThe nipple goes through the tank, the valve shuts the line, the union lets you open it.
Size changeReducer, bush, reducing socketStep 1½″ down to 1″, then ¾″ and ½″ as the taps get fewer.
Bathroom branchReducing tee 25×15The down-line carries on; the branch leaves at ½″.
Every turnElbowFewer turns, better pressure. On a pump suction line a long bend beats an elbow.
Every tap pointFT elbow with metal insertThe tap screws into brass.
Pump, either sideUnion, MTASo the pump can be taken off without cutting pipe. Pipe for the pump: which pipe for the pump.
Geyser inlet and outletCPVC MTAHot side stays CPVC. See geyser line pipe.
The A to Z

Every fitting we keep, drawn and explained

Each card says what it does and what size is on our rack. The link opens its own page.

Turns and branches

Elbow, 90°

Turns a line a quarter turn. Every elbow adds friction, so fewer turns means better pressure on the top floor.

Sch 80 in 15 mm and 40 mm; Prince UPVC 1½″; reducing elbow 1×½

FT elbow, with metal insert

An elbow with a brass insert at one end. The tap or the concealed body screws into brass, not plastic. One behind every tap point. Prince rates insert fittings at 15 kg/cm², lower than a plain fitting but far above a house line.

Sch 80 FT elbow, 15 mm

GI elbow

Galvanised iron for pump and tank stubs where a rigid threaded joint is wanted. It rusts, so plastic is used everywhere else.

GI elbow 1½″

Tee

Branches one line into two.

Prince UPVC tee 1½″

Reducing tee

The main line carries on and a smaller branch leaves to a bathroom.

25×15 mm (Sch 80); 1½×1″ (UPVC)

Four-way tee (cross)

One point that feeds both sides, as when one drop serves two bathrooms back to back.

¾″ four-way

Joins and size changes

Coupler (socket)

Joins two pipe ends for good, with solvent. Use it to repair a cut or extend a run.

Sch 80, 40 mm

Union

Joins with a nut so the line can be opened later without cutting. Put one either side of a pump, before the ball valve at the tank, and before a filter.

Sch 80, 40 mm

Reducer

Steps the pipe size down in the line, for example from the tank outlet to the down-line.

40×25 mm

Bush

Sits inside the socket of a bigger fitting to step it down to a smaller pipe.

1½×1″

Reducing socket

A socket with two sizes, to join a small pipe to a bigger fitting.

1×½″

Threads, taps and ends

MTA, male threaded adapter

A solvent socket at one end and a male thread at the other. It screws into a female thread: a tap, a valve, a pump or a tank. Seal the thread with Teflon tape.

Sch 80 15 mm and 25 mm; UPVC 1½″; CPVC ¾×½″

FTA, female threaded adapter

A solvent socket with a female thread, for a male-threaded part such as a nipple or a tap tail to screw into.

Sch 80, 25 mm

End cap

Closes the end of a pipe, so you can leave a spare point for a later tap or a geyser.

25 mm

Valve and tank

Ball valve

A quarter-turn lever that shuts water off. One at the tank outlet and one at each bathroom branch, so a repair does not mean an empty tank.

1½″

Tank nipple

A threaded tube that passes through the tank wall, held by two nuts and washers. It is the tank outlet that the ball valve screws onto.

1½″

Drain fittings (tee with door, bend with door, P-trap, cowl, clamp) are a different family, on SWR drainage pipes.

Which family

Fittings come in families. Do not mix them.

FamilyForJoined withPage
UPVC Sch 40 / Sch 80Cold water, 5 to 60 °CPVC solventEasyfit
CPVCHot and cold, to 82 °CCPVC solvent onlyCPVC
GI (iron)Pump and tank stubsThreadsGI
SWRDrains, no pressureRubber ring or solventSWR

Why we stock Sch 80 fittings: the fitting is the weak part of a line, not the pipe. At ½″ a Sch 40 pipe is rated 42.40 kg/cm² but a Sch 40 fitting 25.30; a Sch 80 fitting lifts that to 35.85 (Prince). A roof tank gives about 1 kg/cm² and a house pump 3 to 4, so every one of these is safe; Sch 80 simply gives more margin where it costs little.

Mistakes

Four fitting mistakes that cause leaks

Plain elbow at a tap point

A tap screwed into plain plastic can crack the wall. Use an FT elbow, so the thread is brass.

Thread without tape, or over-tightened

Wrap the thread with Teflon tape and tighten by hand and a quarter turn. Over-tightening splits the socket (Prince).

CPVC to UPVC with solvent

The sizes differ. Join them with a threaded adapter and tape.

A line with too many elbows

Each turn costs pressure. Use a bend or a tee where the line can run straight.

How to make the joint right: solvents and tapes. Before the tiles: plumbing stage checklist. A joint that already drips: leaking joints.

Questions people ask us

Short answers

What is an MTA and an FTA?

MTA is a male threaded adapter: solvent socket one end, male thread on the other, to screw into a tap, valve or tank. FTA is the female version, to take a male-threaded part. Both need Teflon tape on the thread.

What is the difference between a coupler and a union?

A coupler joins two pipes for good. A union has a nut so you can open the line later; use it near a pump, a tank valve or a filter.

Why Sch 80 and not Sch 40?

Sch 80 has the thicker wall. A ½″ Sch 80 fitting is rated 35.85 kg/cm² against 25.30 for Sch 40 (Prince), so the weak point of the line has more margin.

Can I use a metal-insert elbow anywhere?

It is meant for tap points. Prince rates insert fittings at 15 kg/cm², lower than a plain Sch 80 fitting, which is plenty for a house line but not a reason to use it where no thread is needed.

Do UPVC fittings fit CPVC pipe?

Not by solvent. CPVC has its own sizes (½″ is 15.9 mm outside). Join the two with a threaded adapter and tape.

I do not see my size on the list.

We can order it. Send the size and fitting on WhatsApp and we tell you how long it takes.

Arun Tiwari
Thekedar · site work, costs and plumbing, Tashya Ventures

Twenty years on sites around Muzaffarpur. Sizes and pressure figures are from Prince's Easyfit page, read on 18 Nov 2026; shapes and uses are standard plumbing.

Where the numbers come from

  1. Prince Pipes, Easyfit UPVC page: size names (15 to 50 mm), outside diameters, Sch 40 and Sch 80 fitting pressures, threaded joints at half rating, insert fittings at 15 kg/cm².
  2. ASTM D2846, CPVC hot and cold water: ½″ CPVC is 15.9 mm outside, which is why it has its own fittings. Standard figure.
  3. Fitting types and their jobs follow general PVC and CPVC fitting guides (elbow turns, tee branches, union opens, bush steps down, adapters join threads to sockets).

Have the plumber's list? Send it.

WhatsApp a photo of the list. We write each fitting with its size, mark what is on the rack and what we order, and send it back with today's price.

TASHYABUILDING SOLUTIONS · MUZAFFARPUR