हिंदी Call90310 74624
Home›Plumbing›CPVC vs UPVC vs PVC vs GI
Compare · pipes

CPVC, UPVC, PVC or GI pipe: which pipe for which line in a Bihar house

The short answer
  • CPVCAnything a geyser feeds: geyser to every hot tap and shower
  • UPVCThe cold supply: pump to tank, tank to every tap
  • PVCDrains (SWR) and the borewell casing, never the house supply
  • GIOnly a short piece at the pump outlet

You don't pick one pipe for the whole house. A good house uses two pipes for water, CPVC where it is hot and UPVC where it is cold, and PVC for everything that drains.

82 °C
CPVC's safe limitPrince's product sheet. Ashirvad says 93 °C; we use the lower figure.
60 °C
UPVC's limitPrince Easyfit is rated for water from 5 to 60 °C. Cold lines only.
50%
Threaded UPVC jointHolds half the pressure of a solvent joint (Prince).
Which pipe runs where
Pipes in a two-storey house, colour-coded A borewell with PVC casing feeds a pump. A short GI piece leaves the pump, then UPVC rises to the roof tank. UPVC runs down from the tank to the taps on both floors and to the geyser inlet. CPVC runs from the geyser to the shower. PVC SWR pipes carry the drains from both floors to the septic tank. 1st floor bathroomground floor bathroom TANK pump geyser septic 1 2 3 4 5 6 1 2 3 4 5 6 GI · pump outlet UPVC · pump to tank UPVC · tank to taps CPVC · geyser to taps PVC SWR · drains PVC · boring casing
Schematic, not to scale. The numbers match the line-by-line notes below. Basin hot taps are fed the same way as the shower.
Side by side

The four pipes, row by row

Every figure is from the maker's own product page or the Indian Standard printed on the pipe. Where a maker gives no figure, the table says so instead of guessing.

  CPVCchlorinated PVC UPVCe.g. Prince Easyfit PVCagri pipe, SWR, casing GIgalvanised iron
Hot waterYes, to 82 °CPrince SmartFit Plus sheet. Ashirvad FlowGuard Plus says 93 °C.No. 5–60 °CPrince Easyfit. Warm tank water is fine; geyser water is not.NoAgri pipe's pressure rating drops to 0.71× at 40 °C (Prince Aquafit leaflet).Takes heatHeat is not its problem. Rust is.
PressurePressure pipeSDR 11. Prince's page prints no pressure figure, so neither do we.½″: 42.4 kg/cm² (Sch 40), 59.75 (Sch 80)At 23 °C, solvent joint. 1″ Sch 40: 31.6.Agri: 2.5 to 12.5 kg/cm² by classIS 4985. SWR and casing: no pressure, they only drain or line a bore.Tested at 50 kg/cm²IS 1239 factory test (5 MPa). Threads are its weak point.
JointCPVC solvent cement only (Prince's is yellow). Pressure-test after 24 h.UPVC solvent cement. Threads at taps and valves; a threaded joint is rated at half.Solvent or rubber ring. Casing: threaded coupling with a ring.Threads (IS 554) with PTFE tape. Needs a threading die and wrenches.
Size systemCTS: ½″ is 15.9 mm outside. Does not fit UPVC fittings.ASTM inch sizes: ½″ is 21.3 mm outside.Metric: 20, 25, 32 mm… Does not fit Easyfit fittings.Nominal bore, BSP threads. Lengths of 4–7 m.
Read on the pipeCPVC · SDR 11 · IS 15778Sch 40 or Sch 80 · ASTM D1785IS 4985 + class (agri) · IS 13592 (SWR) · IS 12818 (casing)IS 1239 · colour band: blue = medium
Iron-rich borewell waterDoes not rustDoes not rust. Lead-free (Prince, Ashirvad).Does not rustRusts from insideonce the zinc (360 g/m² minimum, IS 4736) is worn through.
Life (maker's figure)25 years design life (Prince SmartFit Plus)No figure on Prince's pageNo figure givenNo fixed figure; depends on the water
Cost bandHighest of the plastics, fittings tooMiddle. Sch 80 costs more than Sch 40Lowest per metreHigh, plus slow threading labour
Where we use itGeyser to hot taps and showerPump to tank, tank to every cold tapDrains to septic; borewell casingShort piece at the pump outlet

Swipe the table sideways to see all four pipes.

Today's price for every size: pipe rates. We don't print prices here because they change.

Line by line

Six lines in a house, and the pipe for each

The numbers match the house drawing at the top. This is the list we go through when a customer brings a house plan to the counter.

1Pump outlet

GI or metal fittings, a short piece

The pump shakes and its body gets warm. Ashirvad's own pump-room advice is metal fittings for the first two connections after the pump, then Sch 80 plastic. A short GI nipple and a valve do that job.

2Pump to roof tank

UPVC, Sch 80 near the pump

This line sees the pump's full push and every start and stop. Ashirvad moves to Sch 80 pipe and fittings after the pump. Use solvent joints along the run; keep threads for the valve and the tank.

3Tank to every cold tap

UPVC, Sch 40 is enough

Water falls from the tank by its own weight: about 1 kg/cm² for every 10 m of height (standard figure). That is far below what Sch 40 is rated for. Put a ball valve just after the tank.

4Geyser to hot taps

CPVC, all the way

From the geyser outlet to the shower and every hot tap, CPVC with CPVC solvent. Usual practice is to make the last stretch of the cold pipe into the geyser CPVC too, because heat creeps back up the inlet.

5Drains to the septic tank

PVC SWR, with slope

Soil and waste lines carry no pressure, so they don't need a pressure pipe. They need a steady fall and joints that don't leak smell. SWR pipe (Prince Ultrafit) comes with ring or solvent fittings.

6Borewell casing

PVC casing pipe, IS 12818

Casing lines the bore so the sides don't fall in. It is its own product with threaded couplings and rubber rings, not a supply pipe. Ashirvad says not to use a metal tool on its threads.

PPR is another hot-water pipe, joined by heat welding with a machine. This page sticks to the four pipes most Bihar houses use. We can order PPR for you; ask on WhatsApp how long it takes.

Hot water

Why the geyser line has to be CPVC

Temperature limit of each pipe CPVC is rated up to 82 °C on Prince's sheet and 93 °C on Ashirvad's. UPVC is rated from 5 to 60 °C. Agriculture PVC loses pressure rating as it warms, to 0.71 times at 40 °C. GI takes heat. Between 60 and 82 °C only CPVC is rated. only CPVC CPVCUPVCAgri PVCGI 82 °C · Prince sheet 93 °C · Ashirvad 5–60 °C · Prince rating ×0.71 at 40 °C heat is fine; rust is the limit 020406080100 °C Water temperature the pipe is rated for
Makers' figures: Prince SmartFit Plus and Easyfit pages, Ashirvad FlowGuard Plus page, Prince Aquafit leaflet.

PVC softens as it warms. UPVC is happy with cold water and with a roof tank that has warmed up in the summer sun. A geyser can send water out hotter than UPVC's 60 °C. On that line a UPVC pipe sags between its clamps, and the joint at the geyser starts to weep, usually inside a tiled wall.

Adding chlorine to the plastic, which is what turns PVC into CPVC, lifts the limit. That extra step is also why CPVC costs more, so you pay for it only where the water is hot.

82 or 93 °C? The makers differ

Prince's SmartFit Plus product page says 82 °C. Ashirvad's FlowGuard Plus page, and Prince's own blog, say 93 °C. We go by the lower number from the product sheet. In practice: keep the geyser thermostat well below 82 °C, and don't let anyone fit UPVC after the geyser because "it will be fine for a few years".

Pressure

The pipe is rarely the weak point. The joint is.

Pressure ratings compared Working pressure at 23 °C in kg per square cm. Easyfit half-inch Sch 80 pipe 59.75, Sch 40 pipe 42.4, one-inch Sch 40 pipe 31.6, half-inch Sch 40 fitting 25.3, half-inch Sch 40 threaded 21.2, brass-insert fitting 15, agriculture PVC class 3 at 6 and class 2 at 4. GI factory test 50, which is a test pressure, not a working rating. A house sees about 1 kg from a roof tank and about 3 to 4 from a pump. Easyfit ½″ Sch 80 pipe Easyfit ½″ Sch 40 pipe Easyfit 1″ Sch 40 pipe Sch 40 ½″ fitting ½″ Sch 40, threaded Brass-insert fitting Agri PVC, class 3 Agri PVC, class 2 GI, factory test 59.75 42.431.625.321.21564 50 test pressure, not a working rating 0204060 kg/cm² at 23 °C What a house sees: about 1 (roof tank) to 3–4 (pump)
Easyfit and fitting figures: Prince Easyfit page. Threaded = 50% of the pipe (Prince). Agri classes: Prince Aquafit leaflet. GI: IS 1239 test at 5 MPa. Tank and pump band: standard and usual figures.

Look at the yellow strip on the left of the chart. That is all the pressure a house plumbing line normally sees: about 1 kg/cm² from a roof tank 10 m up, and 3 to 4 kg/cm² from a house pump pushing against a closed valve (usual figure). Every Easyfit pipe and fitting is far above it.

What brings the number down is the joint and the grade:

  • Threads halve it. Prince rates a threaded Easyfit joint at 50% of the solvent-joint figure, and a brass-insert fitting at 15 kg/cm². Use solvent joints along the run and threads only where a tap or valve screws in. If a pipe has to be threaded, usual practice is Sch 80, which has more wall to cut into.
  • Low-class agri pipe has little to spare. Class 2 is 4 kg/cm², about what a pump can push, and the rating drops further in a hot roof run. It also comes in metric sizes, so it doesn't fit Easyfit fittings. Keep it for the field, not the house.
  • Heat lowers every plastic's rating. Prince says so for Easyfit and gives 0.71× at 40 °C for agri pipe. One more reason hot water goes in CPVC.
Sch 40 or Sch 80?Sch 40 for the tank-to-tap lines; Sch 80 near the pump and wherever a pipe gets threaded. The full comparison is on Easyfit Sch 40 vs Sch 80.
The Bihar water angle

Iron in the boring water is what finished GI

Inside a GI pipe and a UPVC pipe after years on iron water A new GI pipe has a zinc layer and a full bore. After years on iron-rich water the zinc is gone and lumps of rust narrow the bore. A UPVC pipe of the same age keeps its full bore; some iron silt may settle but the pipe itself does not rust. GI, new zinc layer, full bore GI, years later zinc gone, rust lumps bore narrowed UPVC, same years full bore; silt can settle, the pipe does not rust
Drawn to show the idea, not measured. Zinc minimum: IS 4736, called up by IS 1239.

Many borewells around Muzaffarpur bring up iron. You see it as orange stains on the bucket and the tiles. In a GI pipe that water works on the zinc coating (360 g/m² at the minimum under IS 4736), and once the zinc is gone, the steel rusts from the inside, where you can't see it. The bore narrows, the pressure at the top floor drops, and the water tastes of iron.

Plastic pipe doesn't rust, so the bore stays open. The iron is still in the water, though: it can settle as silt in a plastic pipe and in the tank, and it still stains taps. Flushing the line and an iron filter deal with that; changing the pipe doesn't.

Where GI still earns its place

A short piece at the pump outlet, where it takes vibration and you can reach it to change it. Not buried in a wall, not as the long line down from the tank.

Old house with GI lines and falling pressure? See low water pressure.

Joints

Same name, different pipe: why CPVC and UPVC don't push together

Half-inch CPVC and half-inch UPVC drawn to scale, and the right way to join them A half-inch CPVC pipe is 15.9 mm outside; a half-inch Easyfit UPVC pipe is 21.3 mm. They are joined through threads: CPVC pipe into a brass-threaded CPVC adaptor, screwed onto a UPVC male threaded adaptor on the UPVC pipe, each side glued with its own solvent. BOTH SOLD AS "½ INCH" · drawn to scale 15.9 mm CPVC ½″ (CTS) 21.3 mm UPVC Easyfit ½″ CPVC UPVC one tin each, never shared THE RIGHT WAY TO JOIN THEM CPVC pipe CPVC solvent brass thread UPVC solvent UPVC pipe
CPVC CTS size: ASTM D2846 (standard figure). Easyfit size: Prince Easyfit page. Some CPVC is also sold in Sch 40/80 inch sizes (Ashirvad lists both); that still needs CPVC solvent.

Half-inch CPVC and half-inch UPVC share a name and nothing else. CPVC for houses is made in copper-tube sizes (CTS), so a ½″ CPVC pipe is 15.9 mm across. A ½″ Easyfit pipe is 21.3 mm. A CPVC fitting will not take a UPVC pipe, and forcing one with extra solvent is a leak waiting for the first hot day.

Each pipe has its own glue

  • CPVC: CPVC solvent cement only. Prince's is yellow; Ashirvad uses a purple primer first, then its own cement. Prince says to wait 24 hours before a pressure test.
  • UPVC: UPVC solvent cement. Prince's steps: cut square, chamfer, deburr, dry-fit, clean, brush the cement on (not by hand), push fully home and hold 1–2 minutes. No hammer.
  • GI: threads and PTFE tape, wrapped in the direction of tightening.

The tin decides more joints than the plumber's hand. If one is already dripping, see leaking pipe joint.

What we see on sites

Six pipe mistakes, and what they cost later

UPVC after the geyser

Later: a weeping joint inside the tiles

Cheaper on the day, but Easyfit is rated to 60 °C. The geyser line has to be CPVC.

One solvent tin for both pipes

Later: joints that let go when hot

Keep a CPVC tin and a UPVC tin on site, labelled. See solvents and tapes.

Agri pipe as the house supply

Later: bursts at pump start, odd fittings

Low classes have little margin over a pump, and metric sizes don't fit Easyfit fittings. Use UPVC.

Threaded joints all along the line

Later: slow drips at every thread

A threaded joint is rated at half. Solvent joints for the run, threads only at taps and valves.

Long GI runs on iron water

Later: low pressure upstairs, orange water

Keep GI to a short piece at the pump. The rest in UPVC.

CPVC for every cold tap too

Later: nothing breaks, but you paid extra

CPVC works cold, but UPVC does that job for less. Spend the difference on good fittings.

Questions people ask us

Short answers

What is the difference between CPVC and UPVC pipe? (CPVC aur UPVC mein fark)

CPVC takes hot water: Prince's SmartFit Plus sheet rates it up to 82 °C and Ashirvad says 93 °C. UPVC is for cold water: Prince rates Easyfit for 5 to 60 °C. CPVC costs more, comes in a different size system (CTS), and needs its own CPVC solvent cement.

Can UPVC pipe take hot water from a geyser?

No. Prince rates Easyfit UPVC for water from 5 to 60 °C. A geyser can send water hotter than that, and the pipe and its joints soften. Warm water from a roof tank in summer is fine in UPVC; anything after the geyser should be CPVC.

Are PVC and UPVC pipes different?

The plastic is much the same; the grade and the job differ. House-supply UPVC such as Prince Easyfit is a thick schedule pipe in inch sizes. The pipe sold as agriculture PVC is made to IS 4985 in pressure classes from 2.5 to 12.5 kg/cm², in metric sizes that do not fit Easyfit fittings. SWR drainage pipe carries no pressure at all. See drainage pipes.

Should I still use GI pipe in a new house?

Only at the pump outlet, where a short metal piece takes vibration. Ashirvad's own advice is metal fittings for the first two connections after the pump, then Sch 80 plastic. For long runs, iron-rich borewell water rusts GI from inside, so use UPVC.

Do I need CPVC for the whole house?

No. CPVC costs more than UPVC, so use it only where water is hot: from the geyser to every hot tap and shower. The cold supply from the tank stays in UPVC. Most houses use both. Today's prices: pipe rates.

Can CPVC and UPVC pipes be joined?

Yes, through threads, not solvent. A half-inch CPVC pipe is 15.9 mm across and a half-inch Easyfit pipe is 21.3 mm, so they do not fit each other. Join them with a brass-threaded CPVC adaptor on one side and a UPVC MTA on the other, each glued with its own solvent.

Is CPVC rated to 82 °C or 93 °C?

The makers differ. Prince's SmartFit Plus product page says 82 °C; Ashirvad's FlowGuard Plus page and Prince's own blog say 93 °C. We use 82 °C, the lower figure from the product sheet, and keep the geyser thermostat below it.

Arun Tiwari
Thekedar · site work, costs and plumbing, Tashya Ventures

Twenty years on sites around Muzaffarpur, where he has pulled out more rusted GI than he can count. Every figure on this page was checked against the maker's own product page or the Indian Standard on 12 Nov 2026. Where makers give different figures, the page says so and uses the safer one.

Where the numbers come from

  1. Prince Pipes, SmartFit Plus CPVC product page: up to 82 °C, 25-year design life, yellow CPVC cement, pressure test after 24 h, terrace and concealed use.
  2. Ashirvad, FlowGuard Plus CPVC page: up to 93 °C, IS 15778, SDR 11/13.5 and Sch 40/80 sizes, purple primer and its own cements.
  3. Prince Pipes, CPVC vs UPVC blog: CPVC up to 93 °C, UPVC around 60 °C, CPVC costs more.
  4. Prince Pipes, Easyfit UPVC page: 5–60 °C, lead-free, Sch 40/80 pressure table at 23 °C (½″ 42.40 / 59.75, 1″ 31.60 kg/cm²), fittings 25.30, metal insert 15, threaded 50%, jointing steps. Prince 2026 price list: Easyfit pipes to ASTM D-1785.
  5. Ashirvad, Aqualife+ UPVC page: lead-free, cold water, pump room: metal fittings for the first two connections, then Sch 80.
  6. Prince Pipes, Aquafit agriculture pipe leaflet: IS 4985, classes 1–6 at 2.5–12.5 kg/cm², derating 0.71 at 40 °C.
  7. Prince Pipes, Ultrafit SWR page: building drainage, 40–160 mm, ring or solvent fittings. Ashirvad, casing pipes page: IS 12818, no metal tools on threads.
  8. IS 1239 (Part 1): 2004, mild steel tubes, as summarised by Infralens: 5 MPa hydro test, colour bands, IS 554 threads, galvanising to IS 4736 at 360 g/m² minimum, 4–7 m lengths.
  9. ASTM D2846 (CPVC hot and cold water, CTS sizes): ½″ CTS is 0.625″ (15.9 mm) outside. Standard figure.

Send us a photo before the tiles go on

WhatsApp a photo of your open plumbing before plaster or tiling, and we'll look at it with you: right pipe on each line, right solvent, threads where they belong.

TASHYABUILDING SOLUTIONS · MUZAFFARPUR
WhatsApp 90310 74624tashyaventures.com