1Cut square
Mark the length all the way round the pipe, then cut square across it. Prince says a hand saw; a ratchet pipe cutter also gives a square cut on house sizes. A slanted cut leaves one side short of the socket.
Cut square, chamfer the edge, clean it dry, brush yellow CPVC cement on the pipe and inside the socket, push it fully home with a quarter turn and hold it still. Then leave it. Prince says wait 24 hours before a pressure test. CPVC never meets UPVC (Easyfit) through solvent; they meet through a threaded adaptor.
Steps you can send to your plumber are below. If a joint already leaks, go to leaking pipe joint.
Steps 1 to 7 are Prince's SmartFit Plus instructions; step 8 is Prince's 24-hour rule and its pressure-test advice. Before you start, check two things: the word CPVC is printed on both the pipe and the fitting, and the cement tin says CPVC and is within its date (Truzo keeps 18 months from manufacture).
Mark the length all the way round the pipe, then cut square across it. Prince says a hand saw; a ratchet pipe cutter also gives a square cut on house sizes. A slanted cut leaves one side short of the socket.
File a small bevel on the outer edge, about 2 mm wide (Prince). A square edge scrapes the cement off the socket wall as it goes in, and that dry strip is where water finds its way out.
Scrape off the rough edges inside and outside with a deburring knife, file or sandpaper. A burr inside catches dirt and slows the flow; a burr outside ploughs the cement off like a square edge.
Push the pipe in without cement. It should go in easily and get tight between one-third and two-thirds of the way (Prince). Mark the full socket depth on the pipe with a pen: this is your check in step 7.
Wipe the pipe end and the inside of the socket with a dry cloth. Dust, oil from hands and water all stop the cement from fusing. Do not join pipes in rain or on a dusty floor.
With the brush in the tin, give the pipe end a full coat up to the pen mark and the inside of the socket a lighter one. Never by hand, and not so much that it pools inside (Prince). Work fast: the next step must happen while it is wet.
One straight push until the pen mark meets the mouth, with a quarter turn to spread the cement. No hammer. Hold it still for 1 to 2 minutes, or the tapered socket pushes the pipe back out. An even bead all round means enough cement; wipe it off.
Leave the joints alone for 24 hours, then pressure-test the whole line with water before anything is plastered or tiled. Prince: never test with air, and an hour of test is enough. More on this below.
For the ½″ to 1″ pipes in a house, yellow one-step CPVC cement needs no primer: Prince uses one-step cement up to 2″ and Truzo is made for CPVC up to 2″. If your pipe's brand asks for a primer first (Ashirvad's system uses a purple one), use it. UPVC (Easyfit) is joined the same way with PVC solvent; its steps and pressure figures are on Prince Easyfit Sch 40 and Sch 80.
The cement keeps working long after the joint feels solid. Prince's own CPVC manual shows how much the weather matters. For ½″ to 1¼″ pipe at 16 to 38 °C, a joint tested up to 10 bar needs 15 minutes, and one tested at 10 to 25 bar needs 6 hours. At 5 to 16 °C they rise to 20 minutes and 12 hours. In damp or humid weather, add half again.
In Muzaffarpur both ends of that chart are real: a monsoon day, and a December morning below 16 °C. That is why we follow Prince's 24 hours for any new line, and why the pressure test comes before plaster, not after.
A leak found now costs one coupler. Found after tiling, it costs the tiles. Prince's testing rules, put in order for a house:
What pressure? Prince says follow local code and never go above the weakest part on the line (a valve, union or thread). Ask your plumber what his hand test pump is set to, and that the needle holds for the hour. The full list for before tiling is on plumbing before tiling.
Half-inch CPVC and half-inch Easyfit share a name and nothing else. House CPVC is made in copper-tube sizes, so ½″ is 15.9 mm across; ½″ Easyfit is 21.34 mm. No amount of cement fills that gap. The full comparison is on CPVC vs UPVC vs PVC vs GI.
The other way round also works: our ¾ × ½ CPVC MTA into an Easyfit FTA. Either way, bring both pieces to the counter and we will screw them together dry before you leave.
Where the change happens in a bathroom (usually on the cold side, with the last stretch into the geyser kept CPVC) is on which pipe for the geyser line. The same rules apply where CPVC meets a brass tap or a GI stub.
Almost every weeping CPVC joint we are asked about comes from one of these. Each one is cheaper to stop on the day than to cut out of a tiled wall.
PVC cement does not bond properly with CPVC (Ashirvad says it plainly). It is the most common mix-up on a site that has one tin of each.
In Bihar heat the cement on the pipe skins over in seconds. Ashirvad calls this a "dry joint". Brush and push in one go, in shade, one joint at a time.
A square end pushes the cement off; a pipe that stops short has half a joint. The pen mark from step 4 shows both at a glance.
Pump pressure pushes a soft joint apart. Wait 24 hours before the test (Prince), and never test with air.
A metal male screwed hard into a plastic female thread splits it. Prince: plastic male into metal female, hand-tight plus half a turn. Plain CPVC male adaptors stay off the hot line.
Same "½ inch" on the label, different sizes. Forcing a fit with extra cement only hides the gap. CPVC to UPVC goes through a thread, as shown above.
A glued joint that already leaks cannot be fixed by painting cement on the outside or tightening harder: it has to be cut out and made again with two couplers. That repair, step by step, is on leaking pipe joint.
One 100 ml tin makes about 30 half-inch joints (worked out from Prince's figure of 300 joints per 946 ml can; a plumber in a hurry gets fewer). Anything not on the rack we can order for you; ask on WhatsApp how long it takes.
Prices are from our latest bill and change often. Please confirm today's rate on WhatsApp or call before buying.
Truzo CPVC solvent cementAstral · yellow · 100 ml · for CPVC up to 2″, never on UPVC₹ 175per tin CPVC pipes and fittingsElbows, tees, couplers, unions · for the hot lineAsk today's rateper piece CPVC MTA, ¾ × ½Brass-threaded male adaptor · CPVC to UPVC or a tap₹ 19per pieceWe sell genuine Prince and Astral with a GST bill. Today's prices: pipe rates.
No. CPVC takes CPVC cement only; Ashirvad says PVC cement does not bond properly with CPVC. The joint often holds at first and lets go months later on the hot line. Prince's CPVC cement and Astral's Truzo are both yellow. Keep the CPVC tin and the PVC tin labelled on site. Which tin is which: solvents and tapes.
Astral's Truzo sheet gives at least 1 hour for a cold line (up to 160 psi) and 6 hours for a hot line (up to 100 psi at 82 °C), for pipe under 1½″. Prince asks for 24 hours before a pressure test. For a new line we wait the 24 hours; for one repaired cold joint, at least an hour, and overnight if it is inside a wall.
1 to 2 minutes, without moving it (Prince's SmartFit Plus page). Astral's Truzo sheet and Prince's own FlowGuard manual say 30 seconds; we use the longer figure because the tapered socket can push the pipe back out.
Not for house sizes with yellow one-step cement. Prince uses one-step cement without primer up to 2″, and Truzo is made for CPVC up to 2″. Primer and heavy orange cement are for 2½″ and above. If your pipe's own brand asks for a primer (Ashirvad's system does), follow it.
Through threads, never through solvent. ½″ CPVC is 15.9 mm outside and ½″ Easyfit is 21.34 mm, so one does not fit the other. Glue a brass-insert CPVC female adaptor on the CPVC with CPVC cement, a UPVC male adaptor on the Easyfit with PVC solvent, tape the male thread and screw them together: hand-tight, then half a turn with a wrench. See MTA and FTA adaptors.
To spread the cement evenly round the joint. Prince's manual says a quarter turn; Truzo's sheet says 45 to 90 degrees. Twisting after the pipe is fully home, or turning it back later, breaks the joint that has started to form.
Prince says a hand saw, cut square. A ratchet pipe cutter does the same job faster on house sizes and leaves a square end. Either way, chamfer and deburr afterwards. We can order a cutter for you.
About 30 half-inch joints. Prince's manual gives about 300 half-inch joints per 946 ml can; scaled down, a 100 ml tin makes about 30. A tin left open thickens and makes fewer, so close it after every joint.
No. Cement painted on the outside of a finished joint does nothing. A leaking glued joint has to be cut out and made again with two couplers. The repair is on leaking pipe joint.
Not in the rain: a wet pipe will not fuse. On a cold morning yes, but wait longer. Prince's chart doubles the cure time for a high-pressure test when it is between 5 and 16 °C, and adds half again in humid weather. In summer, do it in the shade in the cool morning.
Twenty years on sites around Muzaffarpur. The steps and times here are from Prince's CPVC page and manual and Astral's Truzo data sheet, checked on 13 Nov 2026. Where the makers differ, the page says so and uses the safer figure.
WhatsApp us the number of bathrooms and whether there is a geyser. We will send the CPVC, UPVC, adaptors and the right two tins of cement, with today's price.