Water dripping from a pipe joint: which joint it is, and how to fix each kind
- 1Glued (solvent) jointIt cannot be repaired in place. Cut it out and re-join with new couplers and the right solvent.
- 2Threaded jointOpen it, clean it, put on fresh Teflon tape. If the plastic fitting has cracked, replace the MTA or FTA.
- 3Tank nippleEmpty the tank below it and reseat the rubber washer so it sits flat. Then make the nut firm, but don't force it.
Two things never fix a leaking joint: painting more solvent on the outside, and tightening harder. The first does nothing and the second cracks the fitting.
Find the joint that really leaks
Water runs along the underside of a pipe and drips from the lowest point. So the joint that drips is often not the joint that leaks. Five minutes of checking saves you buying the wrong part.
1Shut the water, dry everything
Close the valve or switch the pump off. Wipe the pipe dry on both sides of every joint near the drip, including the top of the pipe.
2Wrap dry tissue round each joint
A strip of toilet paper or newspaper round each joint. Open the water again and wait a few minutes. The first strip that goes wet marks the leak. Mark it with a pen.
3Make sure it is a joint at all
Wet in the middle of a pipe: the pipe is cracked. Wet at the tap handle: it's the tap's washer or cartridge, not the pipe. A damp patch on the wall with no pipe in sight: see finding where the water comes from.
A glued joint that weeps has to be cut out and made again
UPVC and CPVC pipes are joined with solvent cement. It isn't glue: it softens the pipe and the socket so the two fuse into one piece. That is why a leaking glued joint can't be opened, and why solvent smeared on the outside never seals it.
What usually went wrong
- Wrong solvent. PVC solvent on CPVC pipe. Ashirvad says plainly that PVC cement does not bond properly with CPVC. It often holds at first and fails months later on the hot line.
- No chamfer. Prince asks for the pipe end to be chamfered about 2 mm. A square end pushes the solvent off as it goes in.
- Too little solvent, or it dried first. Ashirvad calls this a "dry joint". Too much is also wrong: Prince says not to apply excess.
- Moved or loaded too soon. Prince says to hold the joint 1–2 minutes and never hammer it in. Turning the water on early pushes a soft joint apart.
- Dirty or wet pipe. Prince wants both surfaces wiped clean and dry. Astral says moisture interrupts the solvent.
The fix, step by step
- Shut the water and drain the lineOpen the lowest tap so the pipe empties. A solvent joint can't be made on a wet pipe.
- Cut out the bad jointCut square, about a hand's width either side of the joint, with a pipe cutter or a fine hacksaw. If the joint is at an elbow or tee, that fitting comes out with it.
- Chamfer, deburr, wipeBevel the outer edge of each cut end (Prince: about 2 mm), scrape off the burrs inside and out, and wipe clean and dry.
- Dry-fit the new parts firstNew fitting if one came out, a short piece of pipe, and a coupler at each end. Prince's test: without solvent, the pipe should go about one-third to two-thirds of the way into the socket before it gets tight. Mark the full depth with a pen.
- Brush the right solvent on both surfacesOn the pipe end and inside the socket, with the brush in the tin, not a finger. PVC solvent for UPVC, CPVC solvent for CPVC.
- Push fully home and hold 1–2 minutesOne firm push to the pen mark, with a small turn to spread the solvent, no hammer. Wipe off what squeezes out. Do the next joint only when this one holds.
- Wait before the water goes back onGo by the tin. Astral says at least 1 hour for a cold line, longer for hot water and bigger pipe. We leave a geyser line, or any joint going into a wall, overnight.
| Your pipe | Solvent |
|---|---|
| UPVC water pipePrince Easyfit, Ashirvad, Sch 40 / Sch 80 | Pipefix PVC 101 or Hold PVC, 100 ml |
| CPVC hot and cold pipe"CPVC" is printed along the pipe | Truzo CPVC, 100 ml. Never PVC solvent. |
| SWR drain pipe110 mm toilet line and the like | PVC solvent, or the rubber ring if the pipe has a ring socket |
| GI (iron) pipe | No solvent. Threads and Teflon tape only. |
Might you need to open this line again, say near the pump or a filter? Use a union in place of one coupler. It unscrews, so next time nothing gets cut. Full jointing steps: how to join CPVC and UPVC pipe.
A threaded joint: fresh tape, or a new adaptor if it cracked
Threads are where a plastic line meets a tap, a pump, a valve, a tank nipple or a GI stub, through an MTA (thread outside) or an FTA (thread inside). They leak for three reasons: too little tape, tape wound the wrong way, or a plastic thread forced until it split.
The fix, step by step
- Shut the water and unscrew the jointHold the fitting behind the joint still with a second spanner, so the turn doesn't crack a glued joint further back.
- Clean off all the old tapePick the old tape and dirt out of both threads. Fresh tape over old tape stops the threads meeting.
- Look at the plastic female threadLook along the FTA, or the plastic fitting with the thread inside, for a hairline crack. If you find one, replace that adaptor and don't bother taping.
- Tape the male thread, 3–5 turnsClockwise when you look at the open end, the same way it screws in. Pull it tight into the grooves and leave the first thread bare so no shreds go into the pipe.
- Hand-tight, then a little with the wrenchPrince says to hand-tighten firmly, then use a pipe wrench with rubber packing in its jaws so it doesn't scratch the plastic, and not to over-tighten. Stop when it's firm. Plastic threads split long before metal ones.
- Water on and watch itTape needs no curing. Look again after an hour. Still weeping? Open it once more and add a turn. Don't add force.
Parts: Teflon tape 4 m · MTA and FTA in Sch 80 15 and 25 mm, Prince UPVC 1 1/2", CPVC 3/4 × 1/2 · brass-insert FT elbow 15 mm for taps.
Drip under the tank: reseat the washer, don't crank the nut
The tank nipple is the threaded fitting that passes through the tank wall, with a rubber washer and a nut on each side. The rubber washer does the sealing, not the nut and not tape. If it sits crooked or is cut, water finds the gap however hard the nut is.
Why it drips
- Washer not flat. It was twisted or pinched as the nut went on, or one side sits on a curve or ridge of the tank wall.
- Washer cut, hard or dried out. Old rubber in the sun on the roof goes hard and stops sealing.
- Nut loose, often after someone has leaned on the pipe or the ball valve.
- Nut forced too hard. This squeezes the washer out of place and can crack a plastic tank wall around the hole.
- Tape or solvent on the washer. It gives the water a path. The washer goes on clean and dry.
The fix, step by step
- Empty the tank below the nippleSwitch the pump off and run the taps until the water level falls below the hole. With a ball valve after the nipple, the rest of the house stays dry while you work.
- Undo the pipe side, then the back nutUnscrew the pipe fitting from the nipple, then the back nut, and take the nipple out from inside the tank.
- Check both washers and the wallReplace a washer that is cut, hard or squashed out of shape. Wipe the wall around the hole clean. If the hole is on a curve or a ridge, the washer can't sit flat there. The usual practice is to drill a new hole on a flat face.
- Refit with the washers flat and centredInside washer and flange from inside, outside washer and nut from outside. Keep the nipple still while you turn the nut, so the washer doesn't twist.
- Nut hand-tight, then a quarter turnUse a spanner for the last quarter turn only (usual practice). Tape goes on the outer thread where the pipe fitting screws on, never on the washer.
- Fill the tank and check after an hourA dry nut after an hour of full tank is a good sign. Look again next morning.
Parts: tank nipple 1 1/2" (Prince UPVC; other sizes we order) · ball valve 1 1/2" right after the nipple, so next time you don't have to drain the tank. Tank keeps overflowing? See tank overflow.
Your parts list for this repair
Pick the joint and your pipe. You get the exact small parts to ask for, and you can send the list to us on WhatsApp. Best of all, bring the cut-out piece or the old fitting and we'll match it at the counter.
Ask for
Prices are filled in from today's rate: pipe and fitting rates. A size we don't have on the rack? We can order it for you; ask on WhatsApp for the time it takes.
Prices are from our latest bill and change often. Please confirm today's rate on WhatsApp or call before buying.
PVC solvent: Pipefix 101 or HoldFor UPVC, PVC and SWR · 100 mlAsk today's rateper tin Truzo CPVC solventFor CPVC only, hot and cold · 100 ml₹ 175per tin Teflon (PTFE) tapeFor threads only · 4 m roll₹ 13per rollThe full range of solvents and tapes, and which pipe takes which: solvents and tapes.
Call a plumber when the joint is one of these
An open joint under a sink or on the roof is a job you can do. These four are not: opening them wrong costs more than the plumber.
Inside the wall or under tiles
Damp on the wall along a pipe line. The plumber knows where to open so the least tile and plaster comes off.
On the geyser line
Hot water at pressure. It must be CPVC with CPVC solvent and a proper cure. See the geyser line.
Same joint, second time
Something else is wrong: the pipe is under strain, or the size or the pipe type doesn't match. It needs a look on site.
Old GI pipe or no shut-off
Rusted iron threads snap when you turn them. And with no valve before the joint, it can't be opened without flooding.
Plumbers who buy from us, by area: plumbers in Muzaffarpur. Or send a photo of the joint on WhatsApp and we'll tell you which part it needs.
Short answers
Water is dripping from a pipe joint. What should I do? (pipe jod se paani tapak raha hai, kya karein)
Shut the supply, dry the pipe and find the joint that actually leaks. A glued joint gets cut out and re-joined with new couplers and the right solvent. A threaded joint gets fresh Teflon tape, or a new adaptor if it has cracked. At the tank nut, empty the tank below it and reseat the rubber washer flat.
Can I put more solvent on the outside of a leaking joint?
No. Solvent cement fuses the pipe to the socket only on the surfaces inside the socket. Solvent painted on the outside of a joint that already leaks doesn't reach the gap. The joint has to be cut out and made again.
Why does a CPVC joint leak after a few months?
Most often because PVC solvent went on CPVC pipe. Ashirvad says PVC cement does not bond properly with CPVC. The other causes are a pipe end that wasn't chamfered, too little solvent, and water turned on before the joint cured, especially on the hot line from the geyser.
How many turns of Teflon tape on a thread?
Three to five turns on the male thread, pulled tight into the grooves, wound the way the fitting tightens so it doesn't unwind as you screw in. That is Astral Adhesives' figure; Prince also says to wrap in the direction of tightening. Leave the first thread bare.
Should I just tighten the leaking joint more?
Only if a glance shows the nut is plainly loose. A plastic thread that leaks when firm needs fresh tape, not force. Prince warns against over-tightening, and a split FTA is the usual result.
Why does water drip from the tank nipple?
The rubber washer isn't flat against the tank wall, it is cut or hard, or the back nut is loose. Empty the tank below the nipple, take the nut off, check the washer and the wall, and refit with the washer flat and the nut firm, not forced.
How long before I can turn the water on after re-joining?
Go by the time printed on your solvent tin. Astral says at least one hour for a cold water line, and longer for hot water and bigger pipe. Our advice: leave a geyser line, or any joint going inside a wall, overnight before full pressure.
Will M-seal or tape stop it?
For a day or two, while you get the parts. It isn't a repair on a pressure line, and over a joint inside a wall it only hides a leak that keeps soaking the plaster.
Twenty years on sites around Muzaffarpur. He wrote this page from the leaks he sees every week and checked every step against the makers' own instructions on 12 Nov 2026. Where makers give different figures, the page says so and uses the safer one.
Where the steps and figures come from
- Prince Pipes, Easyfit UPVC: installation guide and pressure tables: square cut, chamfer about 2 mm, deburr, dry fit at 1/3–2/3 of socket depth, clean and dry, solvent by brush and not by hand, no excess, hold 1–2 minutes, no hammer; threads taped in the direction of tightening, hand-tight then wrench with rubber packing, no over-tightening; threaded pipe and fittings rated at 50% working pressure; metal-insert fittings 15 kg/cm².
- Ashirvad, CPVC solvent cement guide: PVC cement does not bond properly with CPVC; dry joints, excess cement and skipped chamfering cause leaks; allow longer cure in humid weather.
- Astral Adhesives, Stopping leaks at threaded connections with PTFE tape: 3–5 wraps, clockwise, threads clean, snug but not forced; tape does not fix cracks or glued joints.
- Astral Adhesives, PVC pipe repair with Solvobond: shut the supply and dry the pipe first; at least 1 hour before water on a cold line, longer for hot water and larger pipe; hold 30 seconds (we use Prince's 1–2 minutes).
- Tank nipple fitting (washer flat, nut hand-tight plus a quarter turn, hole on a flat face) is usual practice among the plumbers who buy from us; no maker sheet was found for it.
Send us a photo of the joint