हिंदी Call90310 74624
Home›Plumbing›Prince Easyfit Sch 40 and Sch 80
Plumbing · Prince · in stock

Prince Easyfit UPVC pipe and Sch 80 fittings in Muzaffarpur: sizes, pressure and what we keep

The short answer

Easyfit is Prince Pipes' UPVC system for cold water. The pipe is lead-free and rated for 5 to 60 °C. We keep Sch 40 pipe in 3 m lengths and Sch 80 fittings; any other size or fitting we can order for you, so ask on WhatsApp how long it takes. Today's price for each size is on the pipe rate board, with GST on the bill.

42.40
kg/cm², ½″ Sch 40 pipeAt 23 °C, solvent-welded. Sch 80 pipe: 59.75.
25.30
kg/cm², ½″ Sch 40 fittingThe fitting is the weak part. A Sch 80 fitting: 35.85.
50%
A threaded jointRated at half the solvent-joint figure (Prince).

One job Easyfit cannot do: the line after a geyser. That is CPVC; see CPVC vs UPVC vs PVC vs GI.

Half-inch Easyfit, end on, to scale
Same outside, thicker wall inside End view of a half-inch Easyfit pipe drawn to scale. Both schedules are 21.34 mm outside. Sch 40 has a 2.77 mm minimum wall and a bore of about 15.8 mm, rated 42.40 kg/cm². Sch 80 has a 3.73 mm wall and a bore of about 13.9 mm, rated 59.75 kg/cm². 21.34 mm outside21.34 mm outside Sch 40 Sch 80 wall 2.77 mmwall 3.73 mm bore ≈ 15.8 mmbore ≈ 13.9 mm 42.40 kg/cm²59.75 kg/cm²
Same outside, thicker wall inside. The bore is worked out from Prince's outside diameter less two minimum walls; Sch 80 leaves about 23% less room for water.
Sizes

Easyfit sizes, walls and pressure, row by row

Every figure is from Prince's own Easyfit page. Sizes are named by nominal bore in mm: 15 mm is the half-inch pipe. Both schedules share one outside diameter, so only the wall changes.

SizeOutside dia. (mm)Min. wall, Sch 40 / Sch 80 (mm)Pipe Sch 40Pipe Sch 80Fitting Sch 40Fitting Sch 80 (ours)
½″
15 mm
21.342.77 / 3.7342.4059.7525.3035.85
¾″
20 mm
26.672.87 / 3.9133.7548.5020.2529.10
1″
25 mm
33.403.38 / 4.5531.6044.2518.9526.55
1¼″
32 mm
42.163.56 / 4.8526.0036.6015.6021.95
1½″
40 mm
48.263.68 / 5.0823.2533.0013.9519.80
2″
50 mm
60.323.91 / 5.5419.6528.1011.7516.85

Swipe the table sideways to see every column.

Pressure is working pressure in kg/cm² at 23 °C with a solvent-welded joint (1 kg/cm² is about 14 psi). Prince gives each wall as the minimum plus a tolerance of 0.5 mm or more. The page also lists 65 to 250 mm; we can order any of them, so ask on WhatsApp. Pipe is made to ASTM D1785 and fittings to ASTM D2466 (Sch 40) and D2467 (Sch 80).

Pressure

The pipe is not the weak part. The fitting is.

Working pressure by size, pipe and fittingGrouped bars for six sizes from half inch to 2 inch: Sch 40 pipe, Sch 80 pipe, Sch 40 fitting and Sch 80 fitting, in kg/cm² at 23 °C. At every size the fitting is rated lower than the pipe. A yellow band at the bottom marks the 1 to 4 kg/cm² a house line normally sees. 0 10 20 30 40 50 60 ½″15 mm ¾″20 mm 1″25 mm 1¼″32 mm 1½″40 mm 2″50 mm Sch 40 pipe Sch 80 pipe Sch 40 fitting Sch 80 fitting House line: 1–4 kg/cm² Same size: the fittingrates below the pipe kg/cm² at 23 °C, solvent-welded joint · Prince Easyfit page
Prince's table, plotted. The yellow strip is what a house line normally sees: about 1 kg/cm² from a roof tank 10 m up, and 3 to 4 from a house pump against a closed valve (standard and usual figures).

Look at any group of bars: the two fitting bars are shorter than the two pipe bars. At ½″ a Sch 40 pipe is rated 42.40 kg/cm² but a Sch 40 fitting of the same size only 25.30. A Sch 80 fitting lifts the joint to 35.85. So a line is as strong as its fitting, and that is why we keep Sch 80 fittings.

Even the lowest bar is many times the yellow strip. For an ordinary house, Easyfit is not short of pressure. What brings the number down in real life:

  • Threads. Prince rates threaded pipes and fittings at 50% of the 23 °C figure, and fittings with a brass insert at 15 kg/cm². Use threads only where a tap or valve screws in.
  • Warm water. Prince says a derating factor must be applied above 23 °C but prints no table for Easyfit. Hindware prints one for its own UPVC pipe: 0.62 at 38 °C, 0.40 at 49 °C and 0.22 at 60 °C. Those are not Prince's numbers, but they show how fast a plastic pipe loses strength as it warms. It is one more reason the geyser line is CPVC.
Which schedule

Sch 40 pipe, Sch 80 fittings, and when to go heavier

Most houses need nothing more than this. The full side-by-side is on Easyfit Sch 40 vs Sch 80.

Tank to taps: Sch 40 pipe

Water falls from the tank by its own weight, about 1 kg/cm² for each 10 m of height. A ½″ Sch 40 pipe is rated 42.40. The pipe is more than enough; the thinner wall also leaves the bore wider.

Pump end and threaded ends: Sch 80

A pump pushes harder and every start and stop knocks the joints. A Sch 80 fitting is rated 35.85 against 25.30 for Sch 40 at ½″. Where a pipe has to be threaded, usual practice is Sch 80 pipe, which has more wall to cut into.

After the geyser: neither

Easyfit stops at 60 °C. Anything a geyser feeds is CPVC, which comes in a different size system and takes only its own cement.

Sch 80 pipe costs more, and its thicker wall narrows the bore: at ½″ about 13.9 mm inside against 15.8 mm. On a long run that costs flow. Which size runs where in a house: pipe size from tank to bathroom.

Reading the tag

What MTA, FTA and "Sch 80 25 mm" mean on the box

How to read an Easyfit fitting tagThree tags as printed on our bills, each split into type, schedule and size. MTA is a male threaded adaptor. Red. Tee is a reducing tee. F T Elbow with MI is a female-threaded elbow with a metal insert. Sch 80 means the thick-wall fitting and the mm figure is the pipe size it takes. MTA male threaded adaptor SCH 80 thick-wall Sch 80 fitting 15 MM (½ IN) pipe size it takes: ½ inch (15 mm) RED. TEE reducing tee (3 openings) SCH 80 thick-wall Sch 80 fitting 25MM (1IN) X 15 main 1 inch (25 mm), side branch 15 mm F T ELBOW female-threaded elbow SCH 80 thick-wall Sch 80 fitting (MI) 15MM (MI) brass insert, takes ½ inch pipe
Three tags as they are printed on our own bills: the type, the wall grade, and the size in mm.

Boxes and bills use shorthand. Read each tag left to right: what it is, the schedule, the size. The size in mm is the nominal bore, so 15 is ½″, 20 is ¾″, 25 is 1″, 32 is 1¼″, 40 is 1½″ and 50 is 2″. The pipe itself is bigger outside (½″ is 21.34 mm).

  • MTA: male threaded adaptor. Glue socket on one side, male thread on the other, for a tank connector or valve.
  • FTA: female threaded adaptor. Glue socket on one side, female thread on the other, for a threaded fitting.
  • F T elbow (MI): a female-threaded elbow with a brass insert. The brass takes the tap's thread; Prince rates these at 15 kg/cm².
  • Red. tee, reducer: a tee or a coupler that changes size, written large side first.
  • Union: a joint you can unscrew to take a line apart later. Coupler joins two pipes for good. End cap closes a line.

Easyfit uses inch-based sizes. A metric pipe such as agri pipe, or a CPVC pipe (½″ is 15.9 mm), will not fit these fittings; that is on the pipe comparison.

Joining

A good solvent joint, in Prince's seven steps

The dry-fit test and the chamferCross-section of a pipe pushed dry into a socket. The pipe should jam between one third and two thirds of the socket depth. Below, a pipe end with its outer edge chamfered about 2 mm wide at 15 degrees. pipe fitting socket 0⅓⅔1 pipe should stop in the green zone depth of the socket, 0 = mouth, 1 = bottom 2 mm · 15° Chamfer the spigot end about 2 mm wide at 15°, then deburr pipe end, side view
Steps 2 and 4 of Prince's list. The green band is Prince's dry-fit rule: the pipe should jam between one third and two thirds of the way in.
  1. Cut the pipe square with a hand saw. Mark it all round first.
  2. Chamfer the outer edge of the end, about 2 mm wide at 15°.
  3. Deburr inside and outside with a knife, file or abrasive paper.
  4. Dry-fit without cement. The pipe should jam between ⅓ and ⅔ of the socket depth.
  5. Clean both ends with a dry cloth: no dust, oil or water.
  6. Brush on a liberal coat of cement after marking the insertion length. Never by hand.
  7. Push straight home, wipe off the excess and hold for 1 to 2 minutes. No hammer.

Threads: clean them, wrap PTFE tape in the direction of tightening, tighten by hand, then a wrench over a rubber pad. Do not over-tighten.

Prince's page gives no set or cure time and no test time, so follow the label on the cement tin before you test the line. CPVC has its own cement and steps: how to join CPVC pipe. A joint already weeping: leaking pipe joint.

On our shelf

The Easyfit pipe and fittings we keep

We sell genuine Prince with a GST bill; to check any pipe, see

Prices are from our latest bill and change often. Please confirm today's rate on WhatsApp or call before buying.

genuine or fake Prince pipe. Any size or fitting not on the rack, we can order for you; ask on WhatsApp how long it takes.

Today's price for every size: pipe rates. More about the brand: Prince Pipes · all UPVC pipes and fittings.

Questions people ask us

Short answers

What is the difference between Sch 40 and Sch 80 Easyfit?

Wall thickness. Both have the same outside diameter, so a ½″ pipe is 21.34 mm outside either way. Sch 40 has a 2.77 mm minimum wall and Sch 80 has 3.73 mm. The thicker wall rates higher (59.75 against 42.40 kg/cm² at 23 °C) and leaves a slightly narrower bore. The full comparison is on Easyfit Sch 40 vs Sch 80.

Is Easyfit pipe lead-free and safe for drinking water?

Prince describes Easyfit as lead-free, non-toxic and suitable for potable water, and the pipe we stock is marked lead-free. Prince's page does not name a certifying body, so we quote only what Prince says.

Can Easyfit carry hot water from a geyser?

No. Prince rates Easyfit for 5 to 60 °C. For anything a geyser feeds, use CPVC. See CPVC vs UPVC vs PVC vs GI.

How much pressure does Easyfit take? Is it enough for a house pump?

At 23 °C, ½″ Sch 40 pipe is rated 42.40 kg/cm² and a Sch 80 fitting of the same size 35.85. A roof tank 10 m up gives about 1 kg/cm² and a house pump against a closed valve 3 to 4 kg/cm² (usual figure). The rating is far above both; the joint and the threads are what to watch.

Can I put a Sch 80 fitting on Sch 40 pipe?

Yes. Prince's table gives one outside diameter for both schedules, so the pipe goes into either fitting. The joint is then rated at the fitting's figure, which is why we keep Sch 80 fittings.

Which Easyfit size is which in inches?

15 mm is ½″, 20 mm is ¾″, 25 mm is 1″, 32 mm is 1¼″, 40 mm is 1½″ and 50 mm is 2″. The mm number is the nominal bore; the pipe's real outside diameter is bigger (½″ is 21.34 mm). Which size runs where in a house: pipe size from tank to bathroom.

Can CPVC and Easyfit be joined?

Not by solvent. ½″ CPVC is 15.9 mm outside and ½″ Easyfit is 21.34 mm, so one does not fit the other's fittings. They meet through threaded adaptors; see the pipe comparison and MTA and FTA adaptors.

Which cement do I use on Easyfit?

A solvent cement made for UPVC or PVC, brushed on, never by hand (Prince's rule). CPVC cement is for CPVC only. Our cement is on PVC solvent.

What is the price of Easyfit pipe in Muzaffarpur?

Our price for each size is on the pipe rate board, with GST on the bill. Pipe is sold per 3 m length. We do not print a price on this page because it changes.

Arun Tiwari
Thekedar · site work, costs and plumbing, Tashya Ventures

Twenty years on sites around Muzaffarpur. Every figure here is from Prince's own Easyfit page, checked on 13 Nov 2026. Where another maker is quoted, the page says so.

Where the numbers come from

  1. Prince Pipes, Easyfit UPVC page: 5–60 °C, lead-free, outside diameter, minimum walls and working pressure of pipe (Sch 40 and Sch 80) and fittings at 23 °C, threaded 50%, metal insert 15 kg/cm², the seven jointing steps.
  2. Prince Pipes, Easyfit iN page: ASTM D1785 for pipe, ASTM D2467 for Sch 80 fittings.
  3. Hindware, UPVC plumbing system page: temperature derating factors for its own UPVC pipe, quoted only as an example of the effect.
  4. Prince Pipes, product catalogue (PDF): the same Easyfit table in print.
  5. Same-page figures for CPVC (½″ = 15.9 mm outside) and for tank and pump pressure: CPVC vs UPVC vs PVC vs GI. Pipe sizes in inches worked out from nominal bore.
  6. Store facts: our own shelf at Rewa Road, as stocked on 13 Nov 2026.

Tell us your bathrooms and floors

WhatsApp the number of bathrooms, the floors and where the tank sits, and we will send a pipe and fitting list with today's price.

TASHYABUILDING SOLUTIONS · MUZAFFARPUR