Pipe size from the roof tank to each bathroom: 1½″, 1″, ¾″, ½″, and where each one changes

The short answer
  1. 1½″Tank outlet
  2. 1″Down-line
  3. ¾″Each bathroom and the kitchen
  4. ½″Each tap

The pipe gets smaller as it feeds fewer taps. The thick part near the tank carries water for the whole house; the thin part near a tap carries water for one tap. Never run ½″ from the tank, and never feed a whole bathroom on ½″.

1″
Down-line, up to 3 bathroomsOn one or two floors, plus the kitchen. More than that: 1½″.
×1.75
¾″ against ½″Water area inside the pipe, from Prince's sizes. That is the gap between one tap and two.
0.18
Top-floor shower, kg/cm²Tank on the same roof. The bathroom that needs a size up most.
The size tree, two-storey house
Pipe sizes from the roof tank to every tap A roof tank with a 1½ inch outlet, ball valve and union. A 40 by 25 reducer steps it to a 1 inch down-line. On each floor a tee takes a ¾ inch branch with its own ball valve into the bathroom, and ½ inch pipes go to the basin, cistern and shower. The kitchen takes its own ¾ inch branch on the ground floor. ROOFFIRST FLOORGROUND FLOOR TANK basincisternshower basincisternshower kitchen sink 1½″ 1″ ¾″ ½″ ¾″ ¾″ 1 2 3 4 5 6
  1. 1Tank nipple, ball valve and union, 1½″. Shuts the whole house off at the tank.
  2. 2Reducer 40×25 steps 1½″ down to 1″, right after the valve.
  3. 3Down-line, 1″, straight down the shaft or outside wall.
  4. 4Tee on the down-line at each bathroom and the kitchen, stepped to ¾″.
  5. 5Branch, ¾″, with its own ball valve at the bathroom door.
  6. 6½″ to each outlet, ending in a threaded elbow at the wall.
Schematic, not to scale; pipe thickness shows size. Cold lines only. The geyser line is CPVC and has its own page: pipe for the geyser line.
Height pushes, the pipe carries

Why the pipe starts thick and ends thin

A roof tank has no pump behind it. All it has is height: about 0.1 kg/cm² for each metre of water above the tap. The pipe decides how much of that little push is left when several taps are open.

1The down-line carries the whole house

Morning bath, the kitchen tap and a flush can all run together, and every drop for them passes through the first few metres below the tank. That is the pipe to make big. Thin it there and every tap in the house shares one narrow throat.

2A branch carries one room

Inside a bathroom, two outlets at a time is normal: the shower and the cistern refilling. A ¾″ branch carries that without the shower going weak when someone flushes.

3The last piece carries one tap

A tap, a cistern or a basin takes ½″. Its own short run is not where water is lost. Going bigger here only adds cost and makes the wall fittings harder to fit.

Inside a pipe, to scale
Bore of ½, ¾, 1 and 1½ inch Easyfit Sch 40 pipe drawn to scale Half inch: 21.3 mm outside, about 15.8 mm inside, area 1 times. Three-quarter inch: 26.7 mm outside, about 20.9 mm inside, 1.75 times. One inch: 33.4 mm outside, about 26.6 mm inside, 2.8 times. One and a half inch: 48.3 mm outside, about 40.9 mm inside, 6.7 times. ½″¾″1″1½″ bore 15.8bore 20.9bore 26.6bore 40.9 mm ×1×1.75×2.8×6.7
Outside size and Sch 40 wall from Prince's Easyfit table; bore worked out from them. Yellow: water area against ½″. Grey ring: the pipe wall.

Size is not pressure. A bigger pipe does not add push; only height or a pump does. What it does is lose less on the way. For the same flow, a ½″ line loses roughly 13 times as much push per metre as a 1″ line, and a ¾″ line about 3 times as much (standard Hazen-Williams formula, using the bores above). On a top-floor shower that only has 0.18 kg/cm² to start with, that loss is the difference between a shower and a trickle. Pressure at each floor: pressure pump for a house.

Where each change happens

The fitting at every step, from tank to tap

Each change in size is made by one fitting. This is the list to give the plumber, or to check against what he has fitted before the walls are closed.

WhereSizeFittingOn our shelf
Hole in the tank1½″Tank nipple, then ball valve and unionThe union lets the valve come off without draining the tank.Tank nipple, ball valve, union, all 1½″
Just after the valve1½″ → 1″Reducer 40×25 (Sch 80)Or a 1½×1 bush in a 1½″ socket.Reducer 40×25 and bush 1½×1
Down the wall1″Straight pipe, as few bends as the route allows1″ UPVC pipe
At each bathroom and the kitchen1″ → ¾″Tee on the down-line, then a 1×¾ bush, or a 1×¾ reducing teeTees; 1×¾ sizes we can order
Bathroom door¾″Ball valve on the branchShut one bathroom for repair, keep the rest running.Ball valve; ¾″ we can order
Inside the bathroom¾″ → ½″¾×½ reducing tee for each outlet, or a ¾″ four-way tee where three lines split¾″ four-way tee; ¾×½ tees we can order
At the wall, behind each tap½″Female-threaded elbow with metal insert (FT elbow), so the tap screws inTeflon tape on the tap thread.FT elbow 15 mm, Teflon tape

If your plumber runs 1″ right into the bathroom and drops ½″ from it, that works too: our reducing tee 25×15 and reducing elbow 1×½ are made for exactly that. What does not work is ½″ before the bathroom door. Joining the pipes: how to join CPVC and UPVC pipe.

When the standard tree is not enough

Four houses that should go one size up, and one that shouldn't bother

The tree above suits most two-storey houses in Muzaffarpur. These are the cases where we tell customers to spend a little more on pipe.

Top-floor bathroom under the tank

Tank on a low pad on the same roof
¾″ branch1″ branch

It has the least height of any outlet: about 0.18 kg/cm² at the shower. It cannot afford to lose any of it in the pipe. Run its branch in 1″ and drop ½″ only at each outlet.

A 6 ft stand under the tank roughly doubles it to 0.37. Tank platform

Bathroom far from the down-line

Branch longer than about 12 m, or many bends
¾″ branch1″ branch

Every metre and every elbow takes a little push away. A long ¾″ run to the back of the house loses far more than the same run in 1″. Better still, bring the down-line closer.

Usual practice; measure the run along the wall, not straight across.

Four or more bathrooms, or three floors

Bigger house, joint family, rented floors
1″ down-line1½″ down-line

More outlets open at the same time. Keep the down-line 1½″ all the way from the tank, with a tee and a bush to ¾″ at each bathroom.

Or two 1″ down-lines from two tank outlets, one per side of the house.

Rain shower, body jets, instant geyser

On any floor fed only by the tank
Pipe won't fix this

These need more push than a roof tank's height gives, however thick the pipe. Plan a booster on that bathroom's line from the start, and lay the line in 1″ so the booster has room to work.

A ground-floor bathroom near the down-line does not need a bigger pipe. It already has a whole storey more height above it, about 0.48 kg/cm² at the shower in a two-storey house. The standard ¾″ branch is plenty.

Picker

The pipe sizes for your house

Answer five questions. You get the down-line, the branch for each bathroom, the push at your weakest shower, and a fittings list to send us. Sizes follow usual practice; heights assume 10 ft floors.

Tank pad means the tank sits on the roof itself. A stand is measured from the roof to the bottom of the tank.

Your sizes

Tank outlet, valve, union1½″Tank nipple, ball valve and union in 1½″.
Down-line——
Branch, each bathroom——
Kitchen branch¾″¾″ to the kitchen, ½″ to the sink tap and any RO or washing-machine point.
To each tap, cistern, basin½″FT elbow with metal insert at the wall.
—

Fittings to ask for (about)

    Material totalAsk rate
    Send this to Arun on WhatsApp

    Pipe length depends on your plan; send a photo of the naksha with this list. Prices are filled in from today's pipe rate.

    What goes wrong

    Four pipe mistakes we see in houses around Muzaffarpur

    ½″ FROM TANK

    ½″ straight from the tank

    You see: every tap weak when two run

    Common in older houses and cheap jobs. The whole house shares a pipe meant for one tap. Change the down-line to 1″; it is usually one straight run and costs less than a pump.

    BATHROOM 1BATHROOM 2 ONE LINE

    Bathrooms in a chain

    You see: one flush, the next shower dies

    One ¾″ line runs through the first bathroom into the second. Each bathroom should take its own branch from the down-line, with its own valve.

    9 ELBOWS

    Elbows everywhere

    You see: a bathroom weaker than its height says

    Each elbow costs as much push as a length of straight pipe. Pipe chased round every beam and door adds up. Plan the route on the naksha: straight runs, few bends.

    ¾″½″ AT THE DOOR

    Reduced to ½″ at the door

    You see: the shower drops when the cistern fills

    The ¾″ comes to the door and the whole bathroom runs on ½″ from there. Keep ¾″ along the bathroom wall and step to ½″ only at each outlet.

    Old GI that has rusted inside behaves like a pipe two sizes smaller. Why we replace it with UPVC: CPVC vs UPVC vs PVC vs GI. Weak water with good pipes: low water pressure, six causes.

    On our shelf for this job

    Pipe and fittings, tank to tap

    We sell genuine Prince and Ashirvad with a GST bill. ¾″ ball valves, 1×¾ bushes and tees, ¾×½ tees, 1½″ pipe and any size not listed we can order for you; ask on WhatsApp for the time it takes. Today's price for every size: pipe rates. Delivery is charged separately; ask for the amount for your site (delivery).

    Questions people ask us

    Short answers

    Which pipe size should come down from the overhead tank? (tanki se kitne inch ka pipe)

    For a house of up to three bathrooms and a kitchen on one or two floors, usual practice is a 1″ down-line, with the tank nipple, ball valve and union in 1½″ and a 40×25 reducer just after them. Four or more bathrooms, or three floors, take a 1½″ down-line.

    Is ½ inch pipe enough for a bathroom?

    Only for the last short piece to each tap, cistern or basin. The line into the bathroom should be ¾″. A ½″ Easyfit pipe has a bore of about 15.8 mm against about 20.9 mm for ¾″, so the ¾″ line has about 1.75 times the water area, and the bathroom doesn't starve when two outlets run together.

    Will a bigger pipe increase water pressure?

    No. The push at a tap comes only from the height of the water in the tank above it, about 0.1 kg/cm² for every metre (standard figure). A bigger pipe loses less of that push on the way when water flows, so the tap gets closer to what the height can give. For more than that, raise the tank or fit a booster: see pressure pump for a house.

    Which bathroom needs the bigger pipe, top floor or ground floor?

    The top floor. A ground-floor bathroom has a whole storey more height above it. A top-floor shower under a tank on the same roof has only about 0.18 kg/cm², so every bit lost in a thin or long pipe shows. Give the top-floor bathrooms, and the one farthest from the down-line, a 1″ branch.

    The shop says "20 mm pipe". Is that ¾ inch?

    For Easyfit and other inch-size UPVC, yes: the mm is the nominal bore, so 15 is ½″, 20 is ¾″, 25 is 1″ and 40 is 1½″. Metric pipes are named by the outside instead, so a 20 mm metric pipe is much thinner inside, nearer a ½″, and doesn't fit inch fittings. Read the print on the pipe; more on Easyfit sizes.

    Is a ¾ inch CPVC pipe the same as a ¾ inch UPVC pipe?

    No. House CPVC is made in copper-tube sizes, so it is smaller outside than UPVC of the same name, and their fittings don't fit each other. Hot lines from the geyser are CPVC; the cold lines on this page are UPVC. They meet through threaded adaptors: CPVC vs UPVC and the geyser line.

    Sch 40 or Sch 80 pipe for the down-line?

    Sch 40 is plenty for a tank line. Prince rates 1″ Easyfit Sch 40 pipe at 31.60 kg/cm² and a 1″ Sch 80 fitting at 26.55, while a roof tank gives about 1 kg/cm² at the ground floor. Sch 40's thinner wall also leaves a wider bore. Use Sch 80 fittings, which is what we keep; details on Easyfit Sch 40 and Sch 80.

    Can I change only the down-line in an old house?

    Yes, and it is often the biggest gain for the least money. If the line leaving the tank is ½″ or old GI, replacing that one run with 1″ UPVC, with a 1½″ ball valve at the tank, helps every tap. Send a photo of the pipe leaving the tank and we will tell you the fittings.

    Arun Tiwari
    Thekedar · site work, costs and plumbing, Tashya Ventures

    Twenty years on sites around Muzaffarpur, many of them spent opening walls to find a ½″ pipe where a 1″ should have been. The pipe sizes on this page were checked against Prince's own Easyfit table on 13 Nov 2026. Sizes per bathroom and per house are usual practice and are labelled so; pressure figures are standard physics.

    Where the numbers come from

    1. Prince Pipes, Easyfit UPVC page: outside diameters (15 mm 21.34, 20 mm 26.67, 25 mm 33.40, 40 mm 48.26), Sch 40 walls (2.77, 2.87, 3.38, 3.68 mm), working pressure at 23 °C (1″ Sch 40 pipe 31.60 kg/cm², 1″ Sch 80 fitting 26.55), threaded joints 50%, 5–60 °C. Bores on this page are outside diameter less two walls.
    2. Standard figure (hydrostatics): 10 m of water = 1 kg/cm², so 0.1 kg/cm² per metre of tank height.
    3. Standard formula (Hazen-Williams): for the same flow, friction loss varies with bore to the power 4.87. With the bores above, ½″ loses about 13 times and ¾″ about 3 times as much per metre as 1″.
    4. Shower pressures (0.18 top floor, 0.37 with a 6 ft stand, 0.48 ground floor): same house as on our pressure pump page, 10 ft floors and water about 0.9 m above the roof.
    5. Size per house, per bathroom and per outlet, and when to go one size up: usual practice in Muzaffarpur, labelled on the page.

    Send us your naksha

    Mark the tank and the bathrooms. We'll send back the pipe sizes, the fittings for each step and today's price on WhatsApp.

    TASHYABUILDING SOLUTIONS · MUZAFFARPUR
    WhatsApp 90310 74624tashyaventures.com