Kitchen plumbing points: the sink's water and waste, the hot line, the RO point, the washing-machine tap, and the drain to the nali

The short answer

Mark these on the kitchen wall before the plaster, all fed by one ¾″ branch with its own stop cock:

  1. Sink cold: ½″ UPVC to a wall tap at about 1050 mm, or an angle valve under the counter for a tap mounted on the sink.
  2. Sink hot, only if you want warm water for utensils: CPVC from an instant geyser above the sink.
  3. RO point: its own ½″ point and small valve beside the purifier, a socket next to it, and a way down for the reject water.
  4. Washing-machine tap, if the machine lives here: a tap at about 1000 mm and a standpipe into a floor trap.
  5. Sink waste: coupling, one bottle trap, 40 mm pipe out through the wall.
  6. Floor trap and the 75 mm line to a gully trap outside and on to the nali. Never into the toilet line.

Put the sink on an outside wall if the plan allows: the drain then goes straight out instead of under the floor.

¾″→½″
SupplyA ¾″ branch into the kitchen, ½″ only for the last run to each point.
40→75
Waste, mm40 mm from the sink, 75 mm for the line outside.
1 in 40
FallAbout 3 inches for every 10 ft of drain, always downhill.
The sink wall, all points
Kitchen sink wall with every plumbing pointFront view of a kitchen wall that is also an outside wall. A three-quarter inch cold branch with its own stop cock runs along the top. Half-inch drops feed an instant geyser, a wall mixer over the sink at about 1050 mm, an RO purifier point with its own valve at about 1100 mm, and a washing-machine tap at about 1000 mm. A red CPVC line carries hot water from the geyser to the mixer. Under the sink a coupling, one bottle trap and a 40 mm pipe go out through the wall and down to a gully trap. A floor trap between the counter and the machine takes the RO reject water and the machine's standpipe, and its 75 mm line runs under the floor with a fall to the same gully trap, which empties to the nali. OUTSIDE outside wall ¾″ branch · its own stop cock instantgeyser hot · CPVC cold ½″UPVC wall mixer ~1050 mm counter ~850 mm sink coupling + jali bottle trap: the one trap 40 mm waste ~430 mm RO socket RO point + valve ~1100 mm reject, always down 75 mm under the floor · falls 1 in 40 to the wall floor trap110×75 washing machine tap ~1000 standpipe gully trap to nali / soak pit
Not to scale sideways; heights roughly to scale from the finished floor and are usual practice. Blue: cold UPVC. Red: hot CPVC. Green: RO. Grey: drain. Only the bottle trap holds water on the sink line: the sink pipe does not go into the floor trap.
Decide this first

Which wall the sink goes on

In most Bihar houses the kitchen is drawn after the bathrooms, and the sink ends up wherever the counter is left. The wall decides how long the drain is, and the drain is the part that blocks.

Sink on an outside wall compared with a sink on an inside wallTwo kitchen plans. In the first the sink sits on the outside wall and its drain goes about one metre straight out to a gully trap. In the second the sink sits on an inside wall, and the drain runs five to six metres under the kitchen floor with two turns, each needing a bend with a cleaning door, before it reaches the outside wall. gully trap · ~1 m A · GOOD sink on the outside wall drain goes straight out outside wall at the top, nali beyond it B · AVOID sink on an inside wall 5–6 m under the floor yellow: each turn needs a bend with a cleaning door
Plan view. Every metre of flat drain under a kitchen floor is a metre where grease settles, and it cannot be reached once the floor is tiled.

1Outside wall

The sink, the floor trap and the machine sit on the wall that faces the nali or the side lane. The drain leaves through the wall within a metre or two and is easy to rod from the gully trap.

2Upstairs kitchen

Plan a sleeve in the slab, or better, take the 75 mm pipe out through the wall and down the outside face to a gully trap at the ground. Keep it apart from the bathroom's WC stack.

3Machine and RO near the sink

Both need water and a drain. Grouping them by the sink keeps one floor trap and one short run. The sockets for them go well away from the tap.

Already have the bathrooms planned? The tank-to-bathroom size page gives the down-line; the kitchen takes its own ¾″ branch off it, with a stop cock, so the kitchen tap can be repaired without shutting the house.

Point by point

What each point needs in the wall

Heights are from the finished floor, for a counter at about 850 mm. They are usual practice, not a maker's rule: if your counter or sink is different, mark the wall from them.

Sink cold water

Every kitchen

½″ UPVC~1050 mm wall tapor angle valve ~450 mm
  • Wall tap or wall mixer: a ½″ FT elbow with brass insert set flush with the tile face, about 200 mm above the counter.
  • Tap mounted on the sink or counter: the point goes under the counter instead, with an angle valve and a connection pipe.
  • A mixer needs its hot and cold points 150 mm apart (usual practice): ask your tap's box.
Choose the tap before the plaster. Which tap needs which point: kitchen tap types.

Sink hot water

Only if you want it

½″ CPVCinstant geyser above sink
  • A 3 L instant geyser on the wall above the sink, fed from the cold line, with a CPVC pipe from its outlet to the hot point.
  • CPVC after the geyser, never UPVC: UPVC is rated to about 60 °C; CPVC to 82 °C (Prince) or 93 °C (Ashirvad).
  • Its switch and wire: same rule as a bathroom geyser (16 A double-pole, no socket).
Pipe, joints and the CPVC-to-UPVC change: geyser line pipe.

RO purifier point

Every new kitchen

½″ point + valve~1100 mm5 A socket
  • Its own ½″ point with a small valve, so the RO can be shut for a filter change while the sink still runs.
  • KENT's manual: the RO will not start below 0.3 kg/cm², and asks for the tank at least 10 ft above the purifier. A ground-floor kitchen under a roof tank is fine; a first-floor kitchen under a low tank may need a pump.
  • Reject water: a pipe that only goes down, to the floor trap or the sink waste. KENT says it must not run higher than the purifier.
Iron water? Filter it before the RO: RO point in the kitchen.

Washing machine

If it lives in the kitchen

½″ tap ~1000 mm40 mm standpipefloor trap
  • A washing-machine tap (with a hose nozzle) just above the machine top.
  • The hose hooks into a 40 mm standpipe that drops into the floor trap. Makers ask for the hose outlet high: Haier 80–100 cm for its front-loaders, Samsung 90–100 cm for its top-loaders, with a standpipe at least 5 cm wide.
  • Never push the hose into the trap water or into the sink waste.
Machine in the bathroom or balcony instead: washing-machine point.
The drain out

From the sink to the nali, in order

Kitchen water is greasy, warm and full of food bits. It takes its own line to the nali or soak pit. The toilet line goes to the septic tank and stays separate.

PartSizeWhy
Sink coupling with jali40 mmSits in the sink hole. The jali stops rice and peel before they reach the pipe.
Bottle trapthe one trap on the sink line40 mmHolds water against drain smell. Its bottom cap opens for cleaning; a glued bend cannot.
Rigid pipe to the wall40 mmstudiomatrx asks for at least 40 mm, ideally 50, never the 32 mm basin size. Rigid, not the ribbed flexible pipe: Prayag notes it clogs faster with oil.
Floor trap with jalimulti floor trap110×75For floor-washing water, the RO reject and the machine standpipe. Not the 125 × 110 P-trap: that one is for an Orissa pan.
The line outsideSWR75 mmFalls about 1 in 40. A bend with a cleaning door wherever it turns.
Gully trapat groundA trap with a grating outside the wall; it can be lifted and cleaned without entering the house.
Nali or soak pit—If there is no lane drain, a soak pit; never the septic tank.
Why one trap, not twoIf the bottle trap's pipe goes into the floor trap, the sink water passes two water seals. The air caught between them slows the sink and makes it gurgle. Plumbing codes abroad forbid it (the International Plumbing Code, section 1002.1: a fixture shall not be double trapped). So the sink's 40 mm pipe goes past the floor trap into the 75 mm line, and the floor trap serves the floor, the RO and the machine.
Two lines leave the house
Kitchen drain and toilet drain kept separateSection through a house. On the left, the kitchen sink drains through a bottle trap and a 40 mm pipe into a 75 mm line falling to a gully trap and then to the nali. On the right, the WC drains through a 110 mm pipe to an inspection chamber and the septic tank. A crossed-out dashed link between the two lines says never join them. KITCHEN BATHROOM gully trap → nali / soak pit 40 mm 75 mm, 1 in 40 chamber → septic tank 110 mm NEVER JOIN
Section, not to scale. Grease from the kitchen line chokes a septic tank and a dry kitchen trap would let the toilet line's gas into the kitchen.

Fitting the coupling and trap step by step, and keeping grease out: kitchen sink drain. Where both lines meet the lane drain: kitchen and bathroom water to the nali.

What goes wrong

Six kitchen plumbing mistakes we see

air caught heretrap 1trap 2

Bottle trap into the floor trap

Slow sink, gurgling

Two water seals in a row hold a pocket of air. Take the sink pipe past the floor trap into the 75 mm line.

grease sits in the sag

Ribbed flexible pipe that sags

Blocks every few months

Its ribs and dips hold oil. Use a rigid 40 mm pipe with a steady fall from the bottle trap to the wall.

hose under water:dirty water pulled back

Machine hose pushed into the trap

Drain water back in the drum, smell in clothes

The hose end must stay above the water, hooked into a standpipe at the height the machine's manual gives.

ROreject pipe goes up

RO reject pipe taken up and over

Reject water runs back into the RO

KENT's manual: the reject pipe must not go higher than the purifier. Plan the RO above the floor trap or sink so its pipe only falls.

flat line: water and grease standright: 1 in 40, all the way

Drain laid flat under the floor

Water stands, smell from the sink

Mark the fall on the wall with a string before the floor is filled, and water test it with the plug in, as in the stage checklist.

no stop cock herea dripping kitchen tap =whole house shut

No stop cock for the kitchen

Every washer change shuts the whole house

A ¾″ ball valve where the kitchen branch leaves the down-line, labelled on the wall.

Your kitchen

Pick your points, get the fittings list

Counts are for the points, from usual practice. Pipe lengths depend on your walls, so send the list with a photo or the naksha and we will add the lengths.

Water points in the wall: 0

Fittings for your kitchen

Send this list on WhatsApp

Prices are given on WhatsApp with today's rate (Ask rate). Items not on our shelf we order for you; ask for the time it takes. Pressure test before plaster: see the stage checklist.

Questions people ask us

Short answers

What size pipe for the kitchen sink drain?

40 mm from the bottle trap to the wall (studiomatrx: at least 40, ideally 50, never the 32 mm basin size), then a 75 mm SWR line outside with a fall of about 1 in 40 to the gully trap.

Can the kitchen drain join the toilet line? (rasoi ka paani toilet line mein)

No. The toilet line goes to the septic tank; kitchen grease chokes it, and a dry trap would bring its gas into the kitchen. Give the kitchen its own 75 mm line to a gully trap and the nali, or a soak pit.

Does the kitchen need a floor trap?

Yes, if the floor is washed, the RO reject or a washing machine drains there. Put it outside the sink cabinet so floor water reaches it. The sink itself drains through its own bottle trap, not into the floor trap.

At what height is the kitchen tap point?

Usual practice: a wall tap or wall mixer about 1050 mm from the finished floor for an 850 mm counter, so the spout clears the sink. A tap on the sink needs its point under the counter at about 450 mm with an angle valve.

Where does the RO's waste water go?

Into the floor trap or the sink waste, through a pipe that only runs down. KENT's manual says the reject pipe must not go higher than the purifier, and its Sterling manual keeps the drain within 3 m.

Does a kitchen need hot water?

Not always. If you want it for oily utensils, a small instant geyser above the sink with a CPVC pipe to a wall mixer is the simplest. UPVC is not for hot water.

Should I fit a grease trap?

For a house kitchen, a jali in the sink, a cleanable bottle trap, a rigid pipe with a fall and a cleaning door at each turn usually do the job. Never pour frying oil down the sink. Blocked already: kitchen sink jam.

Arun Tiwari
Thekedar · site work, costs and plumbing, Tashya Ventures

Twenty years on sites around Muzaffarpur. Heights and the fall are usual practice on local sites and are labelled so; RO, machine and pipe figures are from the makers named below.

Where the facts come from

  1. KENT, Supreme RO manual: does not start below 0.3 kg/cm² inlet pressure; source tank at least 10 ft above the purifier. KENT Sterling Plus manual: drain within 3 m. KENT Prime TC handbook: reject pipe not higher than the purifier.
  2. Haier, front-load drain hose installation: outlet 80–100 cm. Samsung, top-load drain hose guide: 90–100 cm, standpipe at least 5 cm. Your model's manual decides.
  3. Prince Pipes, CPVC vs UPVC: CPVC to 82 °C on Prince's SmartFit Plus page (93 °C is Ashirvad's rating), UPVC about 60 °C. Prince Ultrafit SWR multi floor trap 110 × 75 with jali, as on our bathroom pages.
  4. studiomatrx, Kitchen plumbing cost India: sink waste at least 40 mm, ideally 50; fall about 1 in 40; removable bottle trap.
  5. Prayag, Kitchen plumbing checklist: waste at least 40 mm; ribbed flexible pipes clog faster with oil.
  6. IAPMO, Code Spotlight on double trapping, and the International Plumbing Code section 1002.1: a fixture shall not be double trapped; air between traps slows drainage.
  7. Pipe sizes from the house down-line, ¾″ kitchen branch and ½″ last runs: our tank-to-bathroom size page. Heights and the 150 mm mixer spacing: usual practice.

Send us your kitchen wall

A photo or the naksha with the sink marked. We will mark the points with you and send the fittings with today's price, before the plaster.

TASHYABUILDING SOLUTIONS · MUZAFFARPUR